3
•
If there is a power failure or system crash of the network controller while processing a print job, residual data might still
reside on the hard disk drive(s). The System Administrator should immediately invoke an On Demand Image Overwrite
once the machine has been restored.
•
Once an On Demand Image Overwrite has been initiated by the System Administrator from either the Local UI or Web
UI it can not be aborted by the System Administrator.
The System Administrator also has the option of scheduling either a Standard or Full On Demand Image Overwrite
from the Web UI. Follow the instructions starting on page 8-21 in the
SAG to schedule an On Demand Image Overwrite.
•
Before invoking an On Demand Image Overwrite verify that:
•
There are no active or pending print or scan jobs.
•
There are no new or unaccounted for Dynamic Loadable Modules (DLMs) or other software running on the
machine.
•
There are no active processes that access the hard disk drive(s).
•
No user is logged into a session via network accounting, Xerox Standard Accounting, or the internal auditron, or into
a session accessing a directory on the hard disk drive(s)
3
.
•
After a power on of the machine all subsystems must be properly synced and, if printing of Configuration Reports is
enabled on the device, the Configuration Report must have printed.
•
For any previously initiated On Demand Image Overwrite request the confirmation sheet must have printed.
•
The Embedded Fax card must have the correct software version and must be properly configured.
•
When invoked from the Web UI the status of the completed On Demand Image Overwrite will not appear on the Local
UI but can be ascertained from the On Demand Overwrite Confirmation Report that is printed after the Network
Controller reboots.
•
If an On Demand Image Overwrite fails to complete because of an error or system crash, Xerox recommends that first a
system reboot or software reset be initiated by the System Administrator from either the Local UI or the Web UI and be
allowed to complete; otherwise, the Local UI may become unavailable. If the Local UI does become unavailable the
machine will have to be powered off and then powered on again to allow the system to properly resynchronize. Once
the system reboots or software reset has completed the System Administrator should immediately perform another On
Demand Image Overwrite.
•
If there is a failure in the hard disk drive(s)
a message recommending that an On Demand Image Overwrite be run will
appear on the Local UI screen. An Immediate Image Overwrite Error Sheet will also be printed or may contain
incomplete status information. The System Administrator should immediately perform the requested On Demand
Image Overwrite.
•
The time shown on the On Demand Overwrite progress screen displayed on the Local UI may not reflect Daylight
Savings Time.
•
If an On Demand Image Overwrite is successfully completed, the completion (finish) time shown on the printed On
Demand Overwrite Confirmation Report will be the time that the system shuts down.
•
The System Administrator should perform an On Demand Image Overwrite immediately before a WorkCentre™
7755/7765/7775 Multifunction System is decommissioned, returned, sold or disposed of.
g).
The WorkCentre 7755/7765/7775 supports the use of SSLv2.0, SSLv3.0, RC4 and MD5. However, customers are advised to
set the cyrpto policy of their clients to request either SSLv3.1 or TLSv1.0 and to disallow the use of RC4 and MD5.
h).
For SSL to work properly the machine must be assigned a valid, fully qualified machine name and domain. To set the
machine name and domain:
•
“Accessing CentreWare IS” instructions on page 17 of the SAG.
•
At the Web UI, select the
Properties
tab.
•
Select the following entries from the
Properties
'
Content
menu’:
Connectivity
Æ
Protocols
Æ
IP
.
(Internet Protocol)
•
Enter the domain name in the ‘
Domain Name
’ text box and the machine name in the ‘
Host Name
’ text box inside the
General
group box.
•
Select the [
Apply
] button to save the domain and host names entered.