Once created for a stock, the adjustment is saved and can be selected for that stock for any tray.
The adjustment can be performed by selecting one these buttons:
Auto
or
Manual
.
•
Auto
: The adjustment is done automatically by the press and eliminates the need for you to
interpret printed targets and manually enter adjustment values. This saves time and avoids errors.
Usually
Auto
fixes most image quality issues.
Note:
Always perform the
Auto
adjustment first before performing a manual
adjustment.
•
Manual
: The user performs the adjustment manually, including printing test patterns, interpreting
the printed targets on those patterns, and then manually entering the adjustment values. Use the
Manual
adjustment option only when the
Auto
adjustment does not provide the desired output.
Test Print Information for the Secondary Transfer Voltage Adjustment Option
When using the Test Print option for Secondary Transfer Voltage Adjustment option, two test print
windows display. For more information, refer to the following procedures:
•
Test Print Window 1 for Secondary Transfer Voltage Adjustment
•
Test Print Window 2 for Secondary Transfer Voltage Adjustment
Test Print Window 1 for Secondary Transfer Voltage Adjustment
After selecting either
Auto
or
Manual
, the first Test Print (Auto or Manual) window opens. From this
window, you may select the desired options, such as paper tray, sides imaged, and color mode.
For step-by-step instructions on using the
Auto
and
Manual
adjustment options, refer to the
following procedures:
• Auto:
Using the Auto Adjustment Option for Secondary Transfer Voltage Adjustment
• Manual:
Using the Manual Adjustment Option for Secondary Transfer Voltage Adjustment
Test Print Window 2 for Secondary Transfer Voltage Adjustment
After the press runs a test print, a second Test Print window displays.
For information on which option to use for either the
Auto
or
Manual
adjustment options, refer to
the following procedures:
• Auto:
Using the Auto Adjustment Option for Secondary Transfer Voltage Adjustment
• Manual:
Using the Manual Adjustment Option for Secondary Transfer Voltage Adjustment
Using the Auto Adjustment Option for Secondary Transfer Voltage Adjustment
1. Perform one of the following:
• Copy an existing stock entry. Refer to
.
• Modify or edit an existing stock entry. Refer to
Editing an Existing Stock in the Stock Library
.
2. From the Stock Properties window, select and modify the stock attributes as required, including
entering a new or revised stock name, selecting a stock size, color, and other attributes.
If using the Secondary Transfer Voltage Adjustment option, customize the stock name or include
information in the Comment section to identify the usage of this option. For example name the
stock
Custom STVAdj_Auto
or add a comment stating
This custom stock is using
Secondary Transfer Voltage Auto Adjustment
.
114