Release Notes 

The following information supplements the 13.0 customer user guides 

 

Total Accxes 

An issue has been seen with submitting 150 and 200 dpi color and grayscale images to office printers.  
Submission of 300, 400 and 600 dpi images have been more reliable, though higher resolutions require 
monger processing times. 

Sets 

For 600 DPI engines (6279) the maximum number of ARCH E sized documents that will collate reliably in a set is 
150.  If the documents will not collate properly, one copy of the set will be printed only.  This is for sets created 
using the scanner as well as printed sets submitted across the network. 

 

Controller 

 

Stamp does not appear 

If the user tries to upload a stamp files that contains an invalid format, or if the Accounting Mode is set to 
“Enabled”, no error message will be displayed. The WebPMT screen will display a message that the file was 
uploaded successfully and the stamp’s filename will not appear in the “Printer Resident Stamps” list. To avoid this 
situation, set the Job Accounting mode to “Optional” before uploading stamps. The WebPMT has no knowledge 
of the validity of any file that is sent to the printer. File validation and error handling is done on the printer by the 
FreeFlow Accxes controller. The WebPMT only reports that the file was sent to the printer successfully. 

 

Scaling Interaction with “ANY” 

The media size “ANY” will select the best sheet size for an image to prevent clipping.  If a user specifies a media 
size of “ANY” and a scale factor that makes the image too large for any sheet size and mismatch mode is set to 
scale, the controller will select the largest sheet size and scale the image to fit on it. If this is not the desired 
behavior, a specific sheet size can be selected, or the media mismatch mode can be set to QUERY. 

 

Margins may cause clipping 

If the margins (TOP, BOTTOM, RIGHT and LEFT) are set to a non-zero value (5mm is the default) then that 
amount of whitespace will be added to the image before placing it on the media and could cause part of the 
image to be shifted off the page, or clipped.  To correct this problem set the margins to 0. 

 

CGM Files and Folding 

Certain CGM files contain rotation commands which can confuse the system when folding.  If the title block is not 
visible or the plot is bypassed and not folded, change the title block location to obtain a correctly folded 
document. 

 

TFTP not operational beyond FreeFlow Accxes 12.7 

The Trivial File Transfer Protocol is not operational. The recommendation is to use the FreeFlow Accxes Client 
Tools for job submission to the FreeFlow Accxes controller running 12.7 or higher.. 

 

 

Содержание FREEFLOW ACCXES 13.0 B 141

Страница 1: ...ase Notes Version 13 0 b 141 for 6279 only Contents 2 Introduction 2 Feature Keys 3 Release Deliverables 4 Recommended Configurations 5 Release Installation 6 New Features 7 Release Notes 15 Customer...

Страница 2: ...0 PNG BMP and GIF printing is enabled with a Raster feature key beginning in 12 1 DWF printing is enabled with the AutoCAD feature key beginning in version 12 0 Job Accounting Enables tracking media u...

Страница 3: ...de Format Solution The following executable is provided for the Xerox 6279 Wide Format Solution and supports the Xerox Wide Format Scan System and GFI finisher FRX LVX Controller FRX_LVX_6279_13_0b141...

Страница 4: ...equirements for the various systems and configurations supported by the FreeFlow Accxes controller FRX Controller LVX Controller System Min Recommend Min Recommend Any System with the following featur...

Страница 5: ...only accept the installation when there are no active jobs being processed Accxes Client Tools Download the file named Controller _ Printer _ Accxes_version disk bin A status sheet will be printed an...

Страница 6: ...alAccxes The FreeFlow Accxes 13 0 release includes a new feature allowing the user to make a scan in any mode and have the resulting file print on a remote wide format printer Printer support includes...

Страница 7: ...inter by the FreeFlow Accxes controller The WebPMT only reports that the file was sent to the printer successfully Scaling Interaction with ANY The media size ANY will select the best sheet size for a...

Страница 8: ...Background Suppression The scanner uses the first few inches of a document to determine the background suppression If the first few inches of the document being scanned are not representative of the...

Страница 9: ...e are fewer jobs in the queue the jobs can then be resubmitted or scanned Additionally completed jobs will be removed from the queue display immediately to make room for the newly submitted print jobs...

Страница 10: ...ot be the same Default PostScript Page Size If a PostScript job does not specify a page size either by using a compatibility operator such as letter or a4 or by using the setpagedevice operator PageSi...

Страница 11: ...is common to all WorkCentre WorkCentre Pros and Accxes controllers The algorithm for the Image Overwrite feature is Step 1 Pattern 1 is written to the sectors containing temporary files IIO or to the...

Страница 12: ...dpi be used to increase productivity Installing and removing feature keys The 6279 system must be in an idle state not in a power saving state when installing or removing feature keys In a power savi...

Страница 13: ...s Security b Click on Custom level for the Internet security zone c Scroll down until you reach the category Scripting and set Active Scripting to enabled Add the site to the trusted sites zone a Navi...

Страница 14: ...tch created FreeFlow Accxes faults With FreeFlow Accxes 13 0 build 141 this will no longer occur Multi Page document memory constraint messaging problematic When creating a multi page document if the...

Страница 15: ...15 Page left blank intentionally...

Страница 16: ...A XEROX Corporation 2008 All rights reserved XEROX the sphere of connectivity design XEROX Wide Format 6279 6204 6030 6050 6050A 510 721 8825 8830 8850 Xerox Wide Format Scan System FreeFlow Accxes an...

Отзывы: