PREINSTALLATION
Power cables
4635 LPS power cable lengths are as follows:
System controller:
15 feet/4.5 m
Printer:
15 feet/6 feet/1.8 m/4.5 m (60 Hz)
17 feet/5.1 m (50 Hz, no plug)
PC UI:
6 feet/1.8 m
Peripheral cabinet option:
15 feet/4.5m
Note: Cable length loss must be factored in if equipment is
installed in a raised-floor environment. You should also consider
that part of a cable's length is routed inside the equipment to
connect with interior power or data receptacles.
Cable locations
To run the cables beneath the flooring effectively, you need to
know where the cables enter and exit the printer and the system
controller. Figure 3-11 shows those locations (marked with an X).
Figure 3-11.
Cable enter/exit locations (top view)
Efficiency of use
There are many possible layouts for your LPS. Placement
depends on the type and amount of equipment used and the
size and shape of the room used to house the equipment. Some
possible configurations for LPS components include:
•
Side by side
•
L-shaped
•
Face to face.
Equipment placement should limit operator movements as much
as possible. Here are a few suggestions that may be helpful:
•
Place the system controller as close to the output end of the
printer as possible. This will enable operators to simply reach
over to collect printed materials and check output.
•
Consider the location of supplies in relation to the placement
XEROX 4635 LASER PRINTING SYSTEM INSTALLATION PLANNING GUIDE