9 Troubleshooting
RJ-901C/RJ-900C
Maintenance Manual
9-26
4
E071 error
X overcurrent
Overload
condition in PF
motor (X-axis)
during plotter
operation.
1. Check error history
from "Test: Elec."
of self-diagnosis
function.
2. Set the number of
endurance running
cycles to 50 or more
from "Life: PF
motor" of self-
diagnosis function,
and check if "X
motor error" occurs.
3. Check "Encoder:
PF" from "Test:
Encoder" of self-
diagnosis function.
4. Check if Main
Power Board
normally supplies
DC24V.
5. PF motor assembly
may be defective.
6. Main board
assembly may be
defective.
-
Check connection of
following main board
assembly connectors.
•
PF motor cable
assembly
connector: J107
•
PF_ENC assembly
connector: J129
•
If NG, check
connection of main
board assembly
connector: J129.
•
Replace PF motor
assembly.
•
Replace main board
assembly.
"5.4.7
History
Menu" p.5-17
"4.3.3
Replacing
Main Board
Assembly"
p.4-21
"4.4.1
Replacing PF
Motor
Assembly"
p.4-26
"4.3.3
Replacing
Main Board
Assembly"
p.4-21
5
E079 error
X2 overcurrent
Table 9-7 Symptoms and Check Items for Mechanical Serious Errors (Continued)
No.
Message
Event/
symptom
Check item
Action
Reference
Содержание 7142
Страница 24: ...1 Safety Instructions RJ 901C RJ 900C Maintenance Manual 1 12...
Страница 34: ...2 Product Overview RJ 901C RJ 900C Maintenance Manual 2 10...
Страница 50: ...4 Parts Replacement RJ 901C RJ 900C Maintenance Manual 4 4 Rear Upper Lower Right Front Left...
Страница 118: ...4 Parts Replacement RJ 901C RJ 900C Maintenance Manual 4 72...
Страница 121: ...RJ 901C RJ 900C Maintenance Manual 5 Self Diagnosis Mode 5 3 5 9 9 Media Feed Menu 5 69...
Страница 188: ...5 Self Diagnosis Mode RJ 901C RJ 900C Maintenance Manual 5 70...
Страница 198: ...6 Maintenance Mode2 RJ 901C RJ 900C Maintenance Manual 6 10...
Страница 236: ...7 Adjustment RJ 901C RJ 900C Maintenance Manual 7 38...
Страница 244: ...8 Maintenance RJ 901C RJ 900C Maintenance Manual 8 8...
Страница 340: ......
Страница 341: ......