The inverter can be switched on by means of: 
 

A)

 

Potential free contact

     

B) 5-32 V signal

 

 

Connect the ‘signal in’  

 

    Use ‘signal in’ connectors 

connectors 1 and 2 with    

    2 (+5-32V) and 3 (gnd) 

each other by means of 
a n.o. switch. 

 
 
 
 
 
 
 
 
 

 

If the external signal is lost, the inverter switches off.       
 
 

TURNING OFF THE INVERTER BY AN 

EXTERNAL SIGNAL

 

(reverse operation)

 

Remove the two screws of the housing and open it carefully.  
Change the dip-switches to: 
Dipswitch 

2

 to ON 

Dipswitch 

3

 to OFF   

 
Reconnect the connectors according to the data shown in the previous 
chapter. The inverter will now switch off at the relevant external signal. If 
this signal is not present, the inverter is on. 
 
 

GENERATING A SIGNAL 

 
By using the left connector block ‘signal 
out’, different output signals can be 
generated. This can either be a potential 
free or a signal voltage supply. This way it 
is possible to work with an external 
indicator on the dashboard/control panel 
or an switching an external relay.  
  
 
 
 

+5-32Vdc 

GND 

Содержание PPR-2

Страница 1: ...PPR 2 Geb rui k s aan wijzi ng P a g i n a 2 Us er s m an u al P a g e 5 Bedi e nu ng s an l eitu ng P a g e 8 REMOTE CONTROL NL EN DE...

Страница 2: ...een andere modelreeks of merk dan kan er schade ontstaan aan zowel de inverter als de PPR 2 Fabrieksetting dip switches 1 off 2 off 3 on MONTAGE INSTRUCTIES De vaste kabel van de PPR 2 dient aangeslo...

Страница 3: ...tch setting in Dipswitch 2 op ON Dipswitch 3 op OFF Sluit de connectoren weer aan volgens in het vorige hoofdstuk vermelde gegevens De inverter zal nu bij het betreffende externe signaal uitschakelen...

Страница 4: ...dc 2 N C normaal 12 ofwel 24Vdc bij inschakelen inverter 0Vdc 1 Constant 12 ofwel 24Vdc Dit signaal mag max 0 25A belast worden Afhankelijk van het type inverter 12 of 24Volt heeft men nu een voedings...

Страница 5: ...600 and higher If this PPR 2 is connected to another inverter series or brand it can result in damage to both the inverter and the PPR 2 Factory setting dip switches 1 off 2 off 3 on INSTALLATION INS...

Страница 6: ...it carefully Change the dip switches to Dipswitch 2 to ON Dipswitch 3 to OFF Reconnect the connectors according to the data shown in the previous chapter The inverter will now switch off at the relev...

Страница 7: ...ning on the inverter 0Vdc 1 Constant 12 or 24Vdc Depending on the inverter model 12Vdc or 24Vdc input a supply voltage is available when the inverter is switched on or off Max current is 0 25Amp Now f...

Страница 8: ...llreihe oder Marke angeschlossen kann sowohl der Inverter als auch die PPR 2 besch digt werden Werkseinstellung Dip Schalter 1 off 2 off 3 on MONTAGEANLEITUNG Das feste Kabel der PPR 2 muss am Remote...

Страница 9: ...Schalter Einstellung in Dip Schalter 2 auf ON Dip Schalter 3 auf OFF Schlie en Sie die Konnektoren entsprechend den im vorherigen Kapitel genannten Daten an Der Inverter wird nun bei einem entsprechen...

Страница 10: ...4Vdc at turning on the inverter 0Vdc 1 Constant 12 or 24Vdc Dieses Signal darf max mit 0 25 A belastet werden Je nach Invertertyp 12 oder 24 Volt steht eine Versorgungs spannung zur Verf gung wenn der...

Страница 11: ......

Страница 12: ...V1A Xenteq BV Banmolen 14 5768 ET Meijel NL Tel 0031 0 77 4662067 info xenteq nl www xenteq nl...

Отзывы: