OPERATING INSTRUCTIONS 

 
Before using this battery charger, make sure it is compatible with your battery. Refer to 
the ratings on the battery charger, the specifications in this manual, and your battery 
documentation. Charge only sealed or valve regulated, lead-acid, non-automotive, 
maintenance free rechargeable batteries. Attempting to charge other types of batteries 
may result in battery damage. If the battery is very hot or very cold, allow it to adjust to 
room temperature before starting the charge. 
 

Installation 

For the best performance, mount the charger to a hard, flat, vertical surface near a 
convenient power source and near the location of the battery to be charged (mounting 
screws are not provided). Confirm the mounting surface is strong enough to hold the 
charger in place using the screws you have selected. This charger should be located in a 
dry location. A vertical mounting allows cooling air to flow through the charger and over 
the heat sink fins. Do not operate the charger horizontally or it may over heat. 
 

Battery Type Selection 

A switch is provided for selecting between AGM (Odyssey) and Gel-Cell type batteries. 
This switch should be set to your battery type before connecting the battery. If you 
operate the switch during charge, if the charger is still in bulk mode (steady yellow LED), 
then both the charge and float voltages will be changed. If the charger is in absorption 
charge already (flashing yellow LED), of if it is already in float, then operating the switch 
will only change the float voltage for the current charge. 
 

Charge Program Switch 

A switch is provided for selecting between the standard charge program and a special 
program to be used in heavy-cyclic applications. The standard charge program is 
recommended for all battery types, capacities, and applications - given adequate recharge 
time. However, if you have a limited recharge time and the standard charge program is 
not getting the battery charged in the time available, then the heavy-cyclic charge 
program should be used. The charge mode should be selected before attaching the 
battery, or during the bulk charge (steady yellow LED). The heavy-cyclic charge program 
is not suitable for all battery types and capacities – consult your battery documentation. 
 

Powering Up the Charger 

Plug the charger into the proper power source as indicated on the unit. The charger does 
not have a “power on” indicator and will not give any indications until a battery is 
properly connected. To reduce sparks, the charger should be powered up before attaching 
a battery. Otherwise, there may be a spark as the battery charges up the high frequency 
capacitors inside the charger. In either case, the charger output remains off until a battery 
is properly attached. 
 

Attaching the Battery 

Determine the battery polarity. Most batteries identify the positive terminal with a “+” 
sign or the color red and identify the negative terminal with a “

” sign or the color black. 

Содержание Optimizer SX100-1

Страница 1: ...ev 1 0 October 17 2006 THE EXTREME BATTERY CHARGER For Sales Support and Service phone 407 331 4793 fax 407 331 4708 website www xenotronix com email information xenotronix com Xenotronix TLI Inc 2541...

Страница 2: ...This Warranty does not apply to and is rendered null and void by any Product which after leaving Seller s manufacturing plant a is repaired or altered without Seller s prior written approval b is the...

Страница 3: ...e Charger 3 Attaching the Battery 3 4 Condition Charge Stage 4 Bulk Charge Stage 4 Absorption Charge Stage 4 Equalize Charge Stage 4 Rest Stage 5 Float Charge Stage 5 Battery Disconnect 6 Attaching Lo...

Страница 4: ...e only sealed or valve regulated lead acid non automotive maintenance free rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage o The e...

Страница 5: ...ic undercharging a leading cause of premature battery failure The OPTIMIZER also implements a light conditioning charge to ensure the battery is in good condition and is able to accept a full current...

Страница 6: ...t voltages will be changed If the charger is in absorption charge already flashing yellow LED of if it is already in float then operating the switch will only change the float voltage for the current...

Страница 7: ...advantage over competitive products that reduce in current as the battery voltage rises Approximately 80 of the battery capacity is returned during the bulk charge The bulk charge ends when the charge...

Страница 8: ...arge cycle and wait for a new battery to be attached For best performance the battery should not be disconnected before entering the ready mode If it is necessary to pull a battery off of charge early...

Страница 9: ...float charge Input Fuse This charger is equipped with a non user replaceable fuse If the charge indicator does not light when the battery is attached first check to see that the output cable is not r...

Страница 10: ...tery fault If you with to attempt a charge anyway the battery must be brought to above 8V They may be done using a simple automotive type battery charger or by temporarily attaching a good battery in...

Страница 11: ...c GEL Float Charge Voltage 13 62 Vdc AGM 13 50 Vdc GEL Condition Equalize Current approx 700 mA Equalize Charge Voltage 15 60 Vdc Battery 12 Volts Sealed Lead Acid Input Cable 3 18 AWG 6 long with NEM...