Xenotronix Optimizer SX100-1 Скачать руководство пользователя страница 4

OPTIMIZER

TM

  

SX100-1 

User’s 

Manual 

 

 

 

Xenotronix/TLI  

IMPORTANT SAFETY INSTRUCTIONS 

 

SAVE THESE INSTRUCTIONS

 - This manual contains important safety and operating 

instructions for the Model SX100-1 Battery Charger (OPTIMIZER). Before using the 
battery charger, please read all instructions and cautionary markings on the battery 
charger, the battery, and the product using the battery. 
 

CAUTION

 - To reduce the risk of electric shock: 

o

 

Do not expose unit to rain or moisture - use indoors only. 

o

 

Do not remove cover. There are no user serviceable parts inside. Refer service to 
qualified service personnel. 

o

 

Connect the battery charger directly to a grounding receptacle. An adaptor should 
not be used with this unit. This unit is equipped with a power cord having an 
equipment grounding conductor and a grounding plug (3-prong). The plug must 
be plugged into an outlet that has been properly installed and grounded in 
accordance with all local and national codes and ordinances. 

o

 

Disconnect charger from AC power and battery before attempting any 
maintenance or cleaning. Turning off controls may not reduce this risk. 

 

WARNING 

o

 

Do not attempt to recharge non-rechargeable batteries. Charge only sealed or 
valve regulated, lead-acid, non-automotive, maintenance free rechargeable 
batteries. Attempting to charge other types of batteries may result in personal 
injury and battery damage. 

o

 

The enclosure will become hot during the charge cycle - DO NOT TOUCH! 

 

DANGER

 - Never alter power cord or plug provided. If it will not fit the outlet, replace 

the power cord with one having the correct plug or have a proper outlet installed by an 
electrician. Improper connection will result in the risk of an electric shock or fire. 
 
Make sure cords are located so that they will not be stepped on, tripped over, or otherwise 
subjected to damage or stress. Do not operate this unit with a damaged cord or plug - 
replace them immediately. To reduce the risk of damage to electric plug, pull by plug 
rather than cord when disconnecting unit. 
 
Do not operate charger if it has received a sharp blow, been dropped, or otherwise 
damaged in any way. Do not disassemble charger; incorrect reassembly will result in the 
risk of an electric shock or fire. Refer service to qualified service personnel. 
 
Recharge batteries in well ventilated areas to prevent build-up of explosive gases. 
 
Allow space around unit and adequate air circulation to reduce internal heat buildup. Do 
not place objects on top of the charger or restrict the airflow through the charger and do 
not operate in a small, enclosed space. 

Содержание Optimizer SX100-1

Страница 1: ...ev 1 0 October 17 2006 THE EXTREME BATTERY CHARGER For Sales Support and Service phone 407 331 4793 fax 407 331 4708 website www xenotronix com email information xenotronix com Xenotronix TLI Inc 2541...

Страница 2: ...This Warranty does not apply to and is rendered null and void by any Product which after leaving Seller s manufacturing plant a is repaired or altered without Seller s prior written approval b is the...

Страница 3: ...e Charger 3 Attaching the Battery 3 4 Condition Charge Stage 4 Bulk Charge Stage 4 Absorption Charge Stage 4 Equalize Charge Stage 4 Rest Stage 5 Float Charge Stage 5 Battery Disconnect 6 Attaching Lo...

Страница 4: ...e only sealed or valve regulated lead acid non automotive maintenance free rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage o The e...

Страница 5: ...ic undercharging a leading cause of premature battery failure The OPTIMIZER also implements a light conditioning charge to ensure the battery is in good condition and is able to accept a full current...

Страница 6: ...t voltages will be changed If the charger is in absorption charge already flashing yellow LED of if it is already in float then operating the switch will only change the float voltage for the current...

Страница 7: ...advantage over competitive products that reduce in current as the battery voltage rises Approximately 80 of the battery capacity is returned during the bulk charge The bulk charge ends when the charge...

Страница 8: ...arge cycle and wait for a new battery to be attached For best performance the battery should not be disconnected before entering the ready mode If it is necessary to pull a battery off of charge early...

Страница 9: ...float charge Input Fuse This charger is equipped with a non user replaceable fuse If the charge indicator does not light when the battery is attached first check to see that the output cable is not r...

Страница 10: ...tery fault If you with to attempt a charge anyway the battery must be brought to above 8V They may be done using a simple automotive type battery charger or by temporarily attaching a good battery in...

Страница 11: ...c GEL Float Charge Voltage 13 62 Vdc AGM 13 50 Vdc GEL Condition Equalize Current approx 700 mA Equalize Charge Voltage 15 60 Vdc Battery 12 Volts Sealed Lead Acid Input Cable 3 18 AWG 6 long with NEM...

Отзывы: