capacity). Leave the battery connected to the charger for 16-24 hours to finish 
charging in the float charge mode, or have a unit made with a custom switch 
current to match the battery capacity. 

 
Xenotronix/TLI can make custom units, or modify our existing units, to exactly match 
your charging needs. Call our sales department for technical information and pricing.  
 
Following are 

some

 of the modifications we can perform: 

o

 

Reduce charge current to match your battery capacity 

o

 

Change switch point to match battery and charge rate 

o

 

Adjust float and charge voltages for special conditions or batteries 

o

 

Make charger into a float charger (single stage) 

o

 

Make charger into a parallel charger (for use with loads in parallel with a battery) 

o

 

Provide custom cables and connectors 

o

 

Private labeling 

 
 

TROUBLESHOOTING 

 
NO INDICATOR LIGHT - If the indicator light is dark, check to see if the receptacle is 
controlled by a light switch or power strip switch. If all else appears normal then the 
charger probably needs repair or replacement. 
 
NO CHARGE INDICATOR, NOT CHARGING - If the charger will not go into charge 
mode (yellow indicator) then the battery is probably already charged. Try again with 
another battery which you know is not charged. 
 
FAULT INDICATOR - If the indicator light is red then either the outputs are hooked up 
in reverse or shorted together – make sure of the connection to the battery. Note: A nearly 
completely dead battery (less than one volt) looks like a short to the charger. If you 
suspect the battery is dead, leave the charger on the battery to see if it will go into charge 
mode. The charger will deliver a small amount of current into a dead battery and may 
eventually go into normal charge mode and recover the battery. 
 

 

CHARGER WILL NOT SWITCH INTO FLOAT MODE - If the charger will not switch 
into the float mode, even after 24 hours, then the battery is probably damaged and is not 
properly accepting the charge. Remove the charger and check the open circuit voltage of 
the battery - there should be about 2.15 V/cell for a properly charged battery (divide the 
battery voltage by two to get the number of cells). If the battery voltage looks correct 
then you may be trying to charge a battery which has too large a capacity for the charger 
(see charging notes and tips). 
 
 

Содержание HPX60 Series

Страница 1: ...User s Manual Rev 1 0 October 17 2006 For Sales Support and Service phone 407 331 4793 fax 407 331 4708 website www xenotronix com email information xenotronix com Xenotronix TLI Inc 2541 Tracy Road...

Страница 2: ...is Warranty does not apply to and is rendered null and void by any Product which after leaving Seller s manufacturing plant a is repaired or altered without Seller s prior written approval b is the su...

Страница 3: ...erating Instructions 2 3 Charging Notes and Tips 3 4 Troubleshooting 4 Maintenance Instructions 5 Battery Charger Specifications 5 Battery Recommendations 6 Dimensions 6 Parallel Battery Charger Suppl...

Страница 4: ...maintenance free rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage o The enclosure will become hot during the charge cycle DO NOT TO...

Страница 5: ...metal enclosure to ensure field reliability This unit is designed to automatically switch into a single stage float charge mode when the battery is charged A single stage parallel charger version is...

Страница 6: ...tages when warm This unit incorporates automatic temperature compensation of the output voltage It will increase the charge voltage in cold conditions and decrease charge voltage in warm conditions Fo...

Страница 7: ...placement NO CHARGE INDICATOR NOT CHARGING If the charger will not go into charge mode yellow indicator then the battery is probably already charged Try again with another battery which you know is no...

Страница 8: ...sary use a mild detergent Do not use an abrasive cleanser or spray cleaners directly onto the charger Do not immerse unit in water BATTERY CHARGER SPECIFICATIONS General Conditions 25 C 77 F Operating...

Страница 9: ...charge current to be safely charged Consult the battery manufacturer or Xenotronix TLI Model Battery HPX60 12C400 12 V 40 AH HPX60 24C200 24 V 20 AH AH Ampere hours Lead Acid Batteries are nominally r...

Страница 10: ...UCTION This unit is a Parallel Charger version of the model HPX60 Battery Charger It is designed to simultaneously float charge a battery while supporting or supplementing a parallel load It may also...

Страница 11: ...oad after the battery has received a partial charge This charger can support a continuous load up one half of its rated output current For example If the unit is rated for 1 A it will support a contin...

Отзывы: