Xenotronix HPX60 Series Скачать руководство пользователя страница 10

HPX60 User’s Manual 

 

 

 

Xenotronix/TLI  

Model HPX60 Series 

Automatic Parallel Battery Charger 

 

Supplemental Instructions

 

 
 
 

IMPORTANT PRECAUTIONS 

 
Follow the battery manufacturer’s recommendations when selecting a battery for use with 
this unit. The battery should be able to accept the full rated output current of this unit or 
the battery may be damaged if the load is disconnected with the battery in a discharged 
condition. 
 
When using a load which is greater that the maximum continuous load specification, the 
battery may not charge and may begin to discharge. The use of a low voltage disconnect 
(LVD) is recommended. 
 
Temperature compensation is disabled for parallel charger models. If using the charger in 
an ambient temperature above 35 °C (95 °F) or below 15 °C (59 °F), contact our sales 
department about receiving a custom model calibrated to match your battery and ambient 
temperature requirements exactly. 
 
 

INTRODUCTION

 

 
This unit is a Parallel Charger version of the model HPX60 Battery Charger. It is 
designed to simultaneously float charge a battery while supporting or supplementing a 
parallel load. It may also be used to maintain larger capacity batteries than it would 
normally be able to charge. 
 
 

OPERATING INSTRUCTIONS

 

 
Refer to the instructions in the main manual for connecting the battery. Connect the load 
in parallel with the battery and charger (note the correct polarity if required by the load). 
 
There is one indicator on the front panel. It will light yellow when the unit is operating in 
the constant current mode at about 75% or more of its maximum rated current. In the 
constant current mode the unit is not regulating voltage and the battery may not maintain 
its charge. This unit should not operate continuously in the constant current mode. This 
unit should only go into the constant current mode intermittently as the parallel load 
requires, or when charging a discharged battery. The indicator light will switch from 
yellow to green when the unit is operating in the constant voltage mode at about 75%, or 

Содержание HPX60 Series

Страница 1: ...User s Manual Rev 1 0 October 17 2006 For Sales Support and Service phone 407 331 4793 fax 407 331 4708 website www xenotronix com email information xenotronix com Xenotronix TLI Inc 2541 Tracy Road...

Страница 2: ...is Warranty does not apply to and is rendered null and void by any Product which after leaving Seller s manufacturing plant a is repaired or altered without Seller s prior written approval b is the su...

Страница 3: ...erating Instructions 2 3 Charging Notes and Tips 3 4 Troubleshooting 4 Maintenance Instructions 5 Battery Charger Specifications 5 Battery Recommendations 6 Dimensions 6 Parallel Battery Charger Suppl...

Страница 4: ...maintenance free rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage o The enclosure will become hot during the charge cycle DO NOT TO...

Страница 5: ...metal enclosure to ensure field reliability This unit is designed to automatically switch into a single stage float charge mode when the battery is charged A single stage parallel charger version is...

Страница 6: ...tages when warm This unit incorporates automatic temperature compensation of the output voltage It will increase the charge voltage in cold conditions and decrease charge voltage in warm conditions Fo...

Страница 7: ...placement NO CHARGE INDICATOR NOT CHARGING If the charger will not go into charge mode yellow indicator then the battery is probably already charged Try again with another battery which you know is no...

Страница 8: ...sary use a mild detergent Do not use an abrasive cleanser or spray cleaners directly onto the charger Do not immerse unit in water BATTERY CHARGER SPECIFICATIONS General Conditions 25 C 77 F Operating...

Страница 9: ...charge current to be safely charged Consult the battery manufacturer or Xenotronix TLI Model Battery HPX60 12C400 12 V 40 AH HPX60 24C200 24 V 20 AH AH Ampere hours Lead Acid Batteries are nominally r...

Страница 10: ...UCTION This unit is a Parallel Charger version of the model HPX60 Battery Charger It is designed to simultaneously float charge a battery while supporting or supplementing a parallel load It may also...

Страница 11: ...oad after the battery has received a partial charge This charger can support a continuous load up one half of its rated output current For example If the unit is rated for 1 A it will support a contin...

Отзывы: