  Intensity Change Switch

 

 

①  Power ON / OFF button

 

D. Turn on light & Intensity Change 

 

 

 

 

 

 

 

 

1.

 

Assemble LED control unit and battery pack, then slightly touch Power ON/OFF button to 

turn on. 

 

Check the light comes out from LED lens module. 

  Caution  –  Please  recharge  the  battery  when  its  turned  on,  but  LED  light  comes  off 

after short period of time. 

2.

 

Adjust the intensity change switch for desired brightness. 

Below table will show you the operating time & brightness (lx@WD400mm) according to 

each step.

 

 

LED Lens Module (LLMW) 

Step 

Brightness (lx) @WD400mm 

BTPWS 

Operating 

Time(hour/minutes) 

BTPWL 

Operating 

Time(hour/minutes) 

1

st

 

4,800 

5h 30m 

8h 30m 

2

nd

 

10,000 

2h 20m 

3h 50m 

3

rd

 

15,000 

1h 30m 

2h 40m 

 

3.

 

Adjust LED lens module up-down or left-right to locate the desired position. 

  Caution  –  External  LED  lens  module’s  temperature  will  go  up  to  max.  46℃  during 

usage, so be careful. 

4.

 

After finishing the usage, slightly touch the power ON/OFF button to turn off. 

Содержание L2SW

Страница 1: ...LED Headlight System User Manual Optical Device Medical Device System Engineering XENOSYS CO LTD 2 Venture ro 100 Beon gil Yeonsu gu Incheon 22013 Korea TEL 82 32 875 9811 2 FAX 82 32 875 9813 www xe...

Страница 2: ...e of Contents INTRODUCTION 3 SAFETY PRECAUTIONS 4 FEATURES 7 COMPONENTS 8 FUNCTIONS 9 OPERATING INSTRUCITON 12 BASIC TROUBLESHOOTING 16 SPECIFICATIONS 17 ELECTROMAGNETIC COMPATIBILITY 23 TRANSPORTATIO...

Страница 3: ...is product is the medical device and KFDA approval registration is described like below table Registration No 1909 Certificate No Gyeongin Jesin 07 86 Product Category I A General Instruments Class Cl...

Страница 4: ...avoid the humidity and water 4 Do not use in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide Warning for Power Unit 1 Do not use any undesignated DC power supply excep...

Страница 5: ...se discoloration 7 Avoid the reach of children or pets 8 Maintain the following conditions for storing the product Environment for Storage Transportation Ambient Temperature 10 40 50 104 Relative Humi...

Страница 6: ...s thus if the operating time is shortened after full charge we recommend exchanging new battery 7 Be careful on benzene thinner alcohol volatile flammable fluid and water If those chemicals penetrate...

Страница 7: ...put 100 240 V 50 60 Hz 0 3 A Output 5 V 2 2A 2 Charger Input DC5V 2 2A Output DC4 2V 1 0A 3 Battery Pack BTPWL DC3 7V 620mAh Lithium Polymer 4 Battery Pack BTPWS DC3 7V 380mAh Lithium Polymer 3 Protec...

Страница 8: ...OMPONENTS 1 Basic Components Main Body LED Control Unit LCUW Battery Pack BTPWL 2 pcs BTPWS 2 pcs Charger LCHW Medical DC Power Supply FW8000MUSB05 USB Power Cable USBC KOIKO Mini Driver DRV18 L2SW Un...

Страница 9: ...y Pack BTPWS Refer to page 10 2 2 Charger LCHW Refer to page 11 1 Medical DC Power Supply FW8000MUSB 05 Refer to page 11 1 USB Power Cable USBC 1 KOIKO Mini Driver DRV18 1 Universal Clip 1 Anti curing...

Страница 10: ...inal Adjustable link LED Lens module can move up down and left right side LED Lens Module LLMW Fix Tab hole Bolt position for universal clip or Xenosys TTL frame or loupe fix 2 Battery Pack Battery Ou...

Страница 11: ...Connector Jack Connector jack between DC5V power supply and the plug Charging Terminal The charging will start when the battery has been put on the charger and connect DC5V power supply connected to t...

Страница 12: ...The battery is not completely charged so charge them fully before the first time usage Connect power supply charger to supply the power If the battery is fully charged it will show green light on cha...

Страница 13: ...water or electrolyte flow into the main body 6 In case of malfunctioning stop using immediately and contact the dealer 7 Do not disassemble repair or modify the equipment by unauthorized personnel Cau...

Страница 14: ...ust the intensity change switch for desired brightness Below table will show you the operating time brightness lx WD400mm according to each step LED Lens Module LLMW Step Brightness lx WD400mm BTPWS O...

Страница 15: ...Frame Attached with Universal Clip Pogo pin Battery Output Terminal E How to disassemble the battery pack 1 Sit on the battery pack to fit pogo pin of main body to the battery output terminal of batte...

Страница 16: ...urn off Sit on battery to the charger to check remaining value Re charge the battery The light intensity is not enough Check the intensity is properly adjusted Adjust the intensity step Discharging ti...

Страница 17: ...SW www xenosys co kr 17 BTPWS BTPWL SPECIFICATIONS 1 Measurement Weight A Main Body LED Control Unit LCUW Size Refer to below photo Weight 15 1 g B Battery Pack BTPWS BTPWL Size Refer to below photo W...

Страница 18: ...www xenosys co kr 18 C Charger LCHW Size Refer to below photo Weight 24 g D Medical DC Power Supply FW8000MUSB 05 Size 31 L x41 W x77 H mm Weight 81 g The purpose of green LED is to indicate the powe...

Страница 19: ...Wireless LED Headlight System L2SW www xenosys co kr 19 E USB Power Cable USBC Size 2m Weight 44 g F Anti curing Filter LF08 2 Size Refer to below photo Weight g...

Страница 20: ...Li polymer Operating Time BTPWS Approx 5 hours 30 minutes 1st step mode Minimum Intensity Approx 2 hours 20 minutes 2nd step mode Approx 1 hours 30 minutes 3rd step mode Maximum Intensity Operating T...

Страница 21: ...e LLMW 1st step 4 800 2nd step 10 000 3rd step 15 000 Field of View mm WD400mm 82mm Color Temperature Wavelength Range 6000 K 400 700 nm Visible Uniformity More than 80 WD400mm LED Life Span Guarantee...

Страница 22: ...Wireless LED Headlight System L2SW www xenosys co kr 22 3 Labels A Outer Carton Box B LED Control Unit C Battery Pack...

Страница 23: ...ption to some other equipment around It cannot guarantee that the interruption will not give any influence to specific equipment When the device is powered on you can find out if it generates electrom...

Страница 24: ...e Ambient Temperature Relative Humidity Relative Humidity Pressure Pressure Environment for Transportation Storage Non operating Ambient Temperature Ambient Temperature Relative Humidity Relative Humi...

Страница 25: ...process with excessive temperature and humidity In case of the exposure it will cause the damage to the equipment and out of warranty Especially inside parts of the main body do not allow the contact...

Страница 26: ...om the abuse or improper use warranty will not be applied The repair cost shall be notified prior to the service repair work starts 10 Before sending the equipment need for repair contact the manufact...

Страница 27: ...sys co kr 27 Revision List Version No Release Date Revison Version 1 0 March 12 2020 First version XENOSYS CO LTD 2 Venture ro 100 Beon gil Yeonsu gu Incheon 22013 Korea TEL 032 875 9811 2 FAX 032 875...

Отзывы: