XENO XPTZ22IR Скачать руководство пользователя страница 18

 

12 

 

As the XPTZ22IR is defaulted to TARGET ID 1 (addressed), if you are using more 
than 1 XPTZ22IR on the DVR, it is recommended that you connect the XPTZ22IR to 
CH1 on  your recording device to programme it and work in reverse order from the 
highest number to the lowest e.g. XPT22IR required on DVR channels: 1, 5, 8, 12 

– 

the order of programming would be: 12, 8, 5, & 1.   

DEVICE ID: This 6 digit number is unique to this camera  

CHECK ID: This helps to distinguish between several domes on the same system (see 
note on pg12)  

TARGET ID: This is the address, 001 to 250 

SOFT PROTOCOL: AUTO (Pelco-D & Pelco-P) 

– this cannot be changed 

BAUD RATE: 1200 / 2400 / 4800 / 9600   

 <COMM RESET>: Defaults the comm menu 

SAVE: Save the settings within the COMM menu, failure to do so may mean having to 
reprogram.  

 4.2.2 IR Display  

 

 

 

 

 

 

 

 

 

 

 

WORKING MODE: AUTO / colour / black/white 

TESTING TIME: Time between switching between colour and black/white and vice versa, 
2s to 15s 

OUTPUT POWER: select 40 / 60 / 80 / 100% for the IR output 

ILLUMINATION ON: 1 to 15. This is the level at which the camera will switch between 
colour to black/white and vice versa. 1 = switches to monochrome whilst there is a high 
amount of ambient light. 15 = switches to monochrome whilst there is a low level of 
ambient light.  

AMBIENT LIGHT: This provides information only on the ambient light level and will change 
depending on the available light. 

IR SWITCH ZOOM: 1 to 10. The point at which the magnification of the XPTZ22IR 
switches the IR illumination from short to long range (adaptive illumination).  

                          <IR DISPLAY

 

WORKING MODE   

 

 

AUTO   

TESTING TIME 

 

 

 

08S 

OUTPUT POWER   

 

 

100% 

ILLUMINATION ON 

 

 

AMBIENT LIGHT 

IR SWITCH ZOOM  

 

 

06 

EXIT 

Содержание XPTZ22IR

Страница 1: ...XPTZ22IR Speed dome User Manual...

Страница 2: ...aintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions please contact Norbain Technical Support and Sales Norbain SD 210 Wh...

Страница 3: ...strictly lead free and without the hazardous substances cited in the directive The crossed out wheeled bin mark symbolizes that within the European Union the product must be collected separately at th...

Страница 4: ...om battery power refer to the operating instructions 8 GROUNDING OR POLARIZATION Equipment that is powered through a polarized plug a plug with one blade wider than the other will fit into the power o...

Страница 5: ...cement parts specified by the manufacturer or that have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards 15 SAFETY CHECK Upon...

Страница 6: ...ion 8 3 3 Special Function 9 4 OSD Menu 10 4 1 OSD Main Menu 10 4 2 Dome 11 4 2 1 Comm 11 4 2 2 IR Display 12 4 2 3 Guard tour 13 4 2 4 A B Scan 13 4 2 5 Pan Scan 14 4 2 6 Park Action Home 14 4 3 Came...

Страница 7: ...ogrammable A B Scan Speed 1 9 speed setting available 360 Scan Speed 1 9 speed setting available Preset dwell time 5 60s interval Preset positions 220 Go to Preset Speed 200 s Guard Tours 3 16 preset...

Страница 8: ...o dark or faint BLC Back Light Compensation If the light of background is bright the target in the picture may appear dark or as a shadow BLC enhances exposure of the target in the centre of the pictu...

Страница 9: ...allows the dome to resume its previous preset or status after power is restored By default setting the dome support power up memory which improves the reliability and avoids repeated settings of the...

Страница 10: ...4 2 Installation 2 1 Dimensions Wall bracket Installation Wall bracket included Ceiling bracket Installation XPTZ ADP available separately...

Страница 11: ...uitable for use in this application a As shown in fig 2 1 use the wall mount bracket as a template to mark the fixing points on the wall and drill accordingly you will also require a larger 5th hole f...

Страница 12: ...e camera on can support the combined weight of the XPZT ADP and the camera and that the fixings you use are suitable for use in this application The XPTZ ADP has 3 parts 1 Base of ceiling base plate 2...

Страница 13: ...ca gel thread sealant e g PTFE tape on both threads of the boom to seal from moisture ingress Refit the Dome cup and tighten the security M4 screw Once the cables are connected insert the dome into th...

Страница 14: ...ting the option 2 means editing the content of the option selected 3 2 Basic Function These are examples and actual commands may vary depending on your control method keyboard Moving the Dome Control...

Страница 15: ...t recall number remain the same The following presets are predefined as special functions and cannot be overwritten Note that whilst there are other commands in the Pelco protocol these are relevant t...

Страница 16: ...COMM Baud rate Check bit Data bit Start bit DOME ID Display the dome address VERSION Version will update along with the product upgrading TEMPERATURE Displays the internal temperature Note Protocol ID...

Страница 17: ...the left right commands to move the cursor and up down to change the number Note On CHECK ID it is recommended to work from right to left Once the numbers match go left and then you can navigate down...

Страница 18: ...M menu failure to do so may mean having to reprogram 4 2 2 IR Display WORKING MODE AUTO colour black white TESTING TIME Time between switching between colour and black white and vice versa 2s to 15s O...

Страница 19: ...o 64 1 slowest 64 fastest INIT This resets the Guard tour selected back to defaults this doesn t delete the preset points from the dome CALL Exits the OSD and runs the selected guard tour DELETE Delet...

Страница 20: ...L exits the OSD and runs the A B scan DELETE Deletes the preset points from the scan this doesn t delete the preset points from the dome 4 2 5 Pan Scan PAN SCAN SPEED 1 to 64 1 slowest 64 fastest INIT...

Страница 21: ...reset point waits before moving to the other point RUNNING This will run the park action if there is nothing set it remind you that there is no action set PRIVACY ZONES Not supported on this model ALA...

Страница 22: ...GE English 4 5 Display SYSTEM Select between PAL NTSC operation P AND T Select between On Off for pan tilt angles ACTION Select between On Off e g preset recall number display IR Select between On Off...

Страница 23: ...us 1 Basic Feature of RS 485bus According to industry bus standard of RS 485 RS 485 bus is half duplex communication bus with the characteristic impedance of 120 whose maximum load capacity is 32 payl...

Страница 24: ...18 XPTZ22IR_Manual V1_1_APRIL_15...

Отзывы: