Xeltek Superpro IS416 Series Скачать руководство пользователя страница 29

 

29

 / 

56

 

 

 

 

Normal

 to load the whole file 

 

 

 

Even

 to load the first byte and discard the second byte out of every 

 

 

two bytes 

 

 

 

Odd

 to discard the first byte and load the second byte out of every 

 

 

two bytes 

 

 

 

1st

 

byte

 

of

 

4

 to load first byte and discard the other three bytes out of 

 

 

every four bytes 

 

 

 

2nd

 

byte

 

of

 

4

 to load the second byte and discard the other three bytes 

 

 

out of every four bytes 

 

 

 

3rd

 

byte

 

of

 

4

 to load the third byte and discard the other three bytes 

 

 

out of every four bytes 

 

 

 

4th

 

byte

 

of

 

4

 to load the fourth byte and discard the other three bytes 

 

 

out of every four bytes 

 

 

 

1st

 

2_byte

 

of

 

4

 to load the first two bytes and discard the other two 

 

 

bytes out of every four bytes 

 

 

 

2nd

 

2_byte

 

of

 

4

 to load the last two bytes and discard the other two 

 

 

bytes out of every four bytes   

 

5.

 

Buffer

 

Address

. To indicate a different initial address of the data being 

 

 

loaded into the buffer. 

 

 

6.

 

File

 

Address

. In case the file type has a non-zero start address, enter the data 

 

 

offset address in the

 

File

 

Address

 field. Make sure to enter the correct 

 

 

address, because an incorrect file offset address causes part of the buffer to be 

 

 

filled with FF (or incorrect data). 

7.

 

Buffer

 

clear

 

on

 

data

 

load

. Tick this checkbox will enable the user to fill the 

 

 

data buffers with the specified data. 

 

 

NOTE

: Ticking the checkbox of Custom File will disable most loading option. 

 

 

Содержание Superpro IS416 Series

Страница 1: ...es Ultra Fast In System 16 Channels Programmer of the Future XELTEK 1 Jiangyun Rd Zijin Jiangning Technology Incubation Special Park Jiangning Nanjing P R China Tel 086 025 68161233 Fax 086 025 681612...

Страница 2: ...025 68161233 Fax 025 68161248 sales02 xeltek cn com www xeltek com cn SUPERPRO is the registered trademark of XELTEK Distribution and sales of this product are intended for use by the original purchas...

Страница 3: ...ERPRO IS416 retains all the good features of SUPERPRO IS03 but in addition it is designed to program today s large capacity devices efficiently and effectively Feature Highlights The SUPERPRO includes...

Страница 4: ...e system requirements and the software and hardware installation Detailed explanations on the commands and the programming procedures Information about error messages and common problems An Appendix t...

Страница 5: ...software interface makes all the operations quite user friendly 1 2 Software feature The USB 2 0 Series supports Windows XP Windows Vista Windows 7 Windows 8 Windows 10 etc More than 43 000 types of d...

Страница 6: ...ooting 1 4 System requirements The minimum system configuration requires A desktop or laptop computer with Intel Pentium or an equivalent processor Windows XP Windows Vista and or Windows 7 operating...

Страница 7: ...he CD ROM or by downloading the program from the Xeltek website Instructions for both methods are described below 2 1 1 Software setup from CD 1 Insert the CD into the CD ROM drive 2 If the setup prog...

Страница 8: ...is running a dialog box displays to allow the user choosing a preferred language 2 Select one from the drop down list and click OK to continue 3 An installation wizard will be displayed as illustrated...

Страница 9: ...9 56 4 A License Agreement will be displayed Click I Agree to continue...

Страница 10: ...will be installed Once the destination file folder is selected click Next to proceed 5 Another dialog box will be presented and allow the user to choose whether creating a start menu icon and or a des...

Страница 11: ...11 56 6 Check the previous selections and click Install to start the installation...

Страница 12: ...sing the Windows Vista system the operation system may display the following dialog box to ask you whether to install the software Select Install this driver software anyway 7 Once the installation is...

Страница 13: ...n 2 1 1 Make sure all other programs are closed during the installation process 2 Connect the programmer module to the computer through the USB port 3 Turn on the power switch of the programmer module...

Страница 14: ...you open the application software for the programmer the system automatically starts the initialization If it does not make sure the programmer is securely connected to the computer and that the power...

Страница 15: ...lone mode for production Under PC hosted mode a PC controls the programmer via a high speed USB connection to program a chip Under stand alone mode the user controls the programmer via LCD display wit...

Страница 16: ...to many commands and operations 4 The Programmer Statue Panel shows the state of the current project and programmer 5 The Device Panel shows the connected device 6 The Buffer Panel shows the state of...

Страница 17: ...number 3 2 Programming Procedures This section provides information on steps for common procedures to program devices using SUPERPRO IS416 Before using the programmer to program a device make sure th...

Страница 18: ...pen the Device Selection window choose one of the following options Select the Device Selection icon Select the Device menu and select the Select Device Device option The system then displays the Devi...

Страница 19: ...me Hex or S record files contain non zero file initial address In this case enter the start address in the File Address box To read the data from a master chip complete the following steps oInsert the...

Страница 20: ...ation word you must set the configuration word before programming to ensure that the chip can be used on the target system The configuration words for some devices are contained in the data file There...

Страница 21: ...formation Select Auto to finish all the operations in one step Execute Production Mode to Program Chips in Batches Select Production Mode from the Option menu to program devices in large quantities Th...

Страница 22: ...cted through the hub In normal mode all operations i e selecting devices loading documents and programming are carried out in the programmer that is selected and highlighted at the time being In globa...

Страница 23: ...IC support 16 channels and some only support 4 channels But Most ICs supports 16 channels 16 channel mode Each channel has two names such as A1 and 1 B2 and 5 and so on A1 1 A2 2 A3 3 A4 4 B1 5 B2 6 B...

Страница 24: ...24 56 A 1 B 2 ATE port User can trigger ATE signals to program automatically it s easy for customer to control IS416 by electrical signals And get operation result by IO state of PASS Fail in ATE port...

Страница 25: ...20 mA max 5 SEL4 Input Isolated Flow select input Bit4 2 5 24 VDC 20 mA max 6 SELMOD Input Isolated ATE mode select input 2 5 24 VDC 20 mA max 7 START Input Isolated Input Ground 8 RESET Input Isolat...

Страница 26: ...ted LCD will display what s selected For example assuming there are 4 projects in SD a prj b prj c prj d prj If SEL0 High SEL1 Low SEL2 Low SEL3 Low SEL4 low The select value is b00001 and a prj selec...

Страница 27: ...tion of the SUPERPRO IS416 software It includes the description of the functions and commands that is listed as below File Menu and Tool Bar 4 1 Project Menu 4 2 Device Menu 4 3 Option Menu 4 4 Tool B...

Страница 28: ...a valid Select Load from the File menu to open the Load File dialog box as illustrated below The red labels refer to the numbered notations follow this figure 1 Buffer To select the Buffer name from t...

Страница 29: ...r bytes 1st 2_byte of 4 to load the first two bytes and discard the other two bytes out of every four bytes 2nd 2_byte of 4 to load the last two bytes and discard the other two bytes out of every four...

Страница 30: ...elect Save from the File menu to save data in the current buffer to a disk file A dialog box titled as Save File will be displayed and the saving options are similar to those in section 4 1 1 Load Fil...

Страница 31: ...fer data NOTE The buffer data may differ from the data file due to revisions All Operation Option settings The content of the Auto mode Software module related to the project NOTE The project content...

Страница 32: ...ker generates password by the tool Password Generator please refer to Password Generator for details Then User input the password and load the project 4 2 2 Save Project Files Select Save Project File...

Страница 33: ...e for volume production The stand alone file includes all the information needed for programming the device This enable the user to prepare the project file s before starting the programmer s operatio...

Страница 34: ...ded The default operation speed is high transfer rate where low transfer rate tick the check box is preferable when the sending project operation fails If there are many large project files need to be...

Страница 35: ...removes the password After this the SD card needs to be format using FAT32 file system so as to be compatible to SUPERPRO IS416 One does not have to unlock the SD card to carry out the Erase Password...

Страница 36: ...you wish to display and select OK to quickly move the cursor to the desired location Fill To fill the data in the buffer between the Start and End address For Fuse buffer the data must be 0 or 1 and f...

Страница 37: ...ified width in the address range and select OK Otherwise select Cancel For example if the data buffer address 0 10 HEX is 12 34 56 78 90 AA BB CC DD EE FF 11 22 33 44 55 Then after swapping the data i...

Страница 38: ...formation about the configuration words Set the configuration words according to the requirements of your target system Otherwise you cannot use the device normally even if it is normal when preparing...

Страница 39: ...any items for the configuration word The items may appear on separate tabs or pages Make sure to set all the items on all pages before programming a chip The input of the configuration word can be div...

Страница 40: ...m does not write the configuration word when preparing the program To write the configuration word in these cases select the corresponding item such as Write_Option Some FLASH devices also use the con...

Страница 41: ...tion is checked 3 Unit Setting Select units that to be operated For example if want to operate A1 B1 please select A1 and B1 4 Indicate the mode for verifying the data by selecting one of the Verify M...

Страница 42: ...or 3 2 2 Parameter1 Parameter2 Frequency Most time don t change these default values 3 Pin state after programming Ignore Don t care the pin state of port in programmer after programming Pullup Pin s...

Страница 43: ...c capacity Maybe it s need to wait long time to power on or off The engineers of XELTEK will tell customer how to set these delay time if need to do 6 Control signals before after algorithm Don t care...

Страница 44: ...nt and User Defined This function is not available in stand alone mode NOTE The serial number is the content required by some applications that must be written in a certain area for every chip This in...

Страница 45: ...start value as 30 hexadecimal representation of 0 and the overflow value as 46 1 the hexadecimal representation of a number greater than F where 9 1 A To define the increase of the serial number selec...

Страница 46: ...ine system We offer two ways to do so 1 PLC to receive the trigger and output operation result The PLC in out ports match the electrical interface of production line 2 Extension board We may offer ext...

Страница 47: ...programming successfully completed or failed NOTE Not all programmers include a beeper 4 5 Edit Auto The Auto function organizes the different functions of the device into a sequential group and carri...

Страница 48: ...e Checksum 7 Select device 8 Device information 9 Device configuration word 10 Edit Auto 11 Option 12 Logic test 13 Production mode 14 Factory mode 15 Global settings 16 Help 4 7 Log History Window Us...

Страница 49: ...it 2 Select New to overwrite the existing log file every time the program starts 3 Select Append to add the log file information at the end of the existing log file each time the program starts 4 Ente...

Страница 50: ...tly For example the location of data in buffer as viewed in the Edit Buffer window may be incorrect or you may receive an error message when loading the file such as Invalid file type or all file data...

Страница 51: ...parts by address of the first two bytes and the last two bytes out of every four bytes Program the two parts to two chips respectively When loading the file select the 1st two bytes of 4 as the File M...

Страница 52: ...ew file such as Sample4 for easy loading and programming next time 5 1 4 POF Format Files When programming ALTERA PLD devices the system saves the data in POF format files When loading a POF Format fi...

Страница 53: ...o search or Search Next functions Search pattern not found The system did not find a matched string or ASCII code User chip is MfgID 0089 DeviID 0051 This display on the Operation Information window i...

Страница 54: ...tem displays this message after you select Cancel on the Status bar Can t cancel The Cancel operation has failed Not a project file The file selected is not a project file After the software is update...

Страница 55: ...hen you call so the engineer can guide you through the solution Contact Information XeltekInc 1 Jiangyun Rd Zijin Jiangning Technology Incubation Special Park Jiangning Nanjing P R China General Consu...

Страница 56: ...uter system or network that allows the program to be operated by more than one user at the same time 2 Modify copy or transfer the User s Guide or other documentation or any copy 3 Decompile or disass...

Отзывы: