background image

9 Pre-dive Inspection 

 

Before every dive it is necessary to follow the inspection procedures for checking the correct operation of all BC 
elements. Even if on a given day you have already dived using your BC, before diving again make sure that all of 
its elements are working correctly. 

 

1.

 

Check that no element of the BC show any signs of wear, paying particular attention to the condition 
of webbing, buckles, the outer shell and the LP hose. 

 

2.

 

Check whether all detachable elements are tightened correctly; those are: bolts, valves, hose adapter 
and single tank adapter (if applicable). 

 

3.

 

Check the BC’s oral inflation putting the inflator’s mouthpiece into your mouth and pressing the purge 
button while breathing out. Using this method, inflate the BC to at least half of its volume. 

 

4.

 

Press  the  inflator  button  until  the  automatic  dump  valve  is  activated.  The  automatic  dump  valve 
should open with a characteristic sound. The air supply should stop immediately after release of the 
inflator button. 

 

5.

 

Check  the  correctness  of  manual  operation  (opening)  of  the  dump  valve  by  pulling  on  its  string.  By 
doing so you should release air. 

 

6.

 

Inflate the BC using the inflator button and then press the purge button, checking whether air is being 
released from the oral inflator’s hole. Repeat this step a couple of times. 

 

7.

 

Inflate the BC using the inflator button and leave it fully inflated for 15 minutes. After the 15 minutes 
the  BC  should  remain  full.  If  it  is  not,  do  not  use  it  until  the  defect  is  removed  by  an  authorized 
WreckAndReef service center. 

 

8.

 

During descent, stop at three meters at the most and perform mutual buddy-check, visually inspecting 
the BC against any leakages. Caution: Air bubbles appearing on the outer shell do not necessarily mean 
leakage. They may result from air being stuck in the structure of the fabric or under the inner shell. 

 

 

 

Содержание ZEOS 28

Страница 1: ...ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50 User manual English...

Страница 2: ...oughly In no way can this manual act as a substitute for professional diver training or course Therefore before you start using any of the products described in this manual make sure that you have rel...

Страница 3: ...1 ternberk Czech Republic ZEOS 38 ZEOS 28 HYDROS 50 and HYDOS 40 buoyancy compensators has been certified as compatible with 89 686 EWG directive as far as it contains air compatible with EN 12021 nor...

Страница 4: ...to damage done to the BC or an uncontrolled ascent For bringing objects heavier than 2kg use appropriate equipment such as a lift bag 7 To prevent the BC from damage avoid prolonged exposure of your...

Страница 5: ...ed with any harness which has two mounting holes of 12mm and a spacing of 11 inches However we recommend using one of high quality CE certified xDEEP harnesses BC design 1 Outer shell 2 K Type Power I...

Страница 6: ...etal which makes the inflator more resistant to freezing and it can be operated much longer than inflators made entirely of plastic The inflator is equipped with an inflator button 1 to inflate the BC...

Страница 7: ...del of harness specific details on connecting its elements are included in its manual Harness straps and crotch strap are adjusted by moving the triglide fastener stopper along the webbing Proceed as...

Страница 8: ...nto the quick connector step 2 as presented in the pictures below Fig 11 LP hose connection step 2 Fig 10 LP hose connection step 1 LP hose connection using the 1 st stage of the regulator must be mad...

Страница 9: ...the pictures below Before connecting the tank carefully wet the connecting straps Otherwise they may loosen and the tank may slip out Danger An incorrectly connected tank may unexpectedly detach from...

Страница 10: ...nk in proper and safe way read and understand the user manual delivered with the double set To install the BC on double tank set 1 Put the double tank set in the stable surface to have bolts on the to...

Страница 11: ...tic dump valve is activated The automatic dump valve should open with a characteristic sound The air supply should stop immediately after release of the inflator button 5 Check the correctness of manu...

Страница 12: ...cy you should press the inflator button for a short moment If more air needs to be added to the BC press the inflator button for a short moment several times During release of air from the BC hold the...

Страница 13: ...inse the BC inside press the purge button of the inflator and fill the BC approximately full with water by means of a garden hose spout or other source of fresh water Rotate the BC several times and n...

Страница 14: ...ugh identical by all appearances may have slightly different properties which may negatively affect the working life of the BC The only maintenance procedure which may be performed by the user is rins...

Страница 15: ...ut harness ZEOS 28 1 05 kg ZEOS 38 1 2 kg HYDROS 40 1 2 kg HYDROS 50 1 3 kg Inflator Type K type Supply pressure Between 6 bar and 17 23 bar 250 PSI Permissible tank parameters Tank type ZEOS 28 and Z...

Страница 16: ...WRECKANDREEF Piotr Czernik Ul Ogrodnik w 3 43 227 G ra Polska Tel 48 12 44 66 998 e mail biuro xdeep pl...

Отзывы: