Low voltage alarm

When the battery voltage lower than 10.5V (×2/24V), the controller enter into the state

of low voltage protection, the

icon appears in the bottom of the LCD and the

icon flickers. The load is disconnected in order to prevent it from over discharging. At
this time, you need to charge the battery. When the battery voltage return to the low
voltage recovery 12.2V (×2/24V), the load output restart.

Short circuit

When short circuit occurs, it shows as the right figure. The controller will not recover

after trying to recover for ten times. At this time, you need to shortly press the
button to turn off the load output, and then the system return to normal work.

Over temperature protection: when the temperature of the controller higher than 70

, the charge and discharge of the controller stop

working. When the temperature of the controller less than 65

, the controller returns to the previous working state.

GUARANTEE

Customer Name

Telephone

Model

E-mail

Bar Code No.

Purchase Area

Address

After-Sales Service

1. After the product has sold, if the function failure occurs, you can choose change or repair it within

months.

2. Warranty:

years upon the date of purchase. If the product exceeds the warranty period or do not belong to the free

repair, our company repair center is still dedicated to serve you.

3. Man-made damage, disassemble the product by yourself, product appearance damage and improper use, all of these may cause
the invalidation of product guarantee.

Содержание UES-2410

Страница 1: ...14 7V 29 4V Low voltage recovery 12 2V 24 4V Low voltage protection 10 5V 21 0V USB output voltage current 5V 2A Characteristic No load loss 10mA Temperature compensation 3mV cell Operation temperature 20 60 Dimension of controller 152 80 2 30mm L W H Package size 163 95 40mm L W H Weight 200g Parameters may customized by customers Visual LCD graphic symbol Brief key operation Automatic identifica...

Страница 2: ...arameters minus button load output switch Parameters Display As shown in the installation connection diagram the battery solar panel load and controller should be connected by turns Please connect the battery first and then the solar panel or load Pay attention that the positive and negative polarity are consistent with the controller ...

Страница 3: ...rface keep pressing the button for 5 seconds the figure flickers it means the controller enters into the setting mode At this time you can press the button to adjust the parameters After finish setting the parameters shortly press the button and the controller will save the set parameters automatically At this interface when there is no operation for 20 seconds it will automatically exit the setti...

Страница 4: ...en the system return to normal work Over temperature protection when the temperature of the controller higher than 70 the charge and discharge of the controller stop working When the temperature of the controller less than 65 the controller returns to the previous working state GUARANTEE Customer Name Telephone Model E mail Bar Code No Purchase Area Address After Sales Service 1 After the product ...

Отзывы: