9
Instructions
Initial Configuration / Master User Setup
1. Make sure
i-touch™
and
Autocloser™
are wired properly and are powered
with the 9V adapter found in the
i-touch™
box. A standard 6V
Autocloser™
power supply will not work to power both devices and should not be used.
2. Short
Autocloser™
GA+ and GA– terminals. This step
is
required for to en-
ter setup (Cut and strip a small piece of the supplied wire and connect both
terminals together).
3. Create a Master User. This Master User is the only one who has the ability to
add/delete other users. The Master User can either create a Master Finger-
print [abbreviated MF] or Master Code [abbreviated MC] as described below.
Only one authorization method [MF or MC] can be established as the master.
To change the Master User (or the master’s authorization method), these
steps must be repeated and all user data will be deleted.
4. To establish a Master User, enter the master setup code by pressing the
FUNC
key, then the
0/SETUP
key. The
INPUT
LED will now be lit.
5. Enter the eight digit setup code
92358766
followed by the
ENTER
key. If the
code is entered correctly then all LEDs will blink in sequence, followed by a
flashing
ACCEPT
LED, followed by a solid
INPUT
LED. Any preexisting fin-
gerprints or access codes are now erased and the unit is prepared to accept
a MC or MF. If
ERROR
LED is flashing, verify step 2.
HINT: setup code ‘92358766’ is the first 8 characters of “Xceltronix” as
seen on a touch tone phone keypad.
6. If a MC is preferred, skip to step 7. To input a MF, wait until the
INPUT
LED
begins to blink. No keys should be pressed before the
INPUT
LED begins
flashing. The Master User should place their finger on the sensor appropri-
ately. When the
INPUT
LED stops blinking, remove the finger from the sen-
sor. This process is repeated up to five times to ensure an accurate reading.
If the MF profile is accepted, the
ACCEPT
LED will flash and the device will
enter normal operating mode. If an error occurs, the
ERROR
LED will light,
and the setup process must be repeated.
7. To input a MC, while the
INPUT
LED remains lit constantly, immediately en-
ter an eight digit code of your choosing followed by the
ENTER
key. This
code cannot duplicate the setup code or consist of all zeros. (Should the
IN-
PUT
LED start flashing, the input period for a MC has expired and setup
process must be repeated.) If the MC is accepted, the
ACCEPT
LED will
flash and the device will enter normal operating mode.
NOTE: The MC is only used for authorizing secure functions. It cannot
be used for entry/exit purposes.
8. Remove short between
Autocloser™
GA+ and GA– terminals.
9. The system is now ready to accept user fingerprints, user codes, or to syn-
chronize with the