5 Technical requirements

5.1 Cell operating conditions

Charge temperature 0 ~ 45°C, Discharge temperature -20 ~ 60°C

5.2 Cell testing conditions

Unless otherwise specified, all tests stated should be done at 25 ± 2°C.

5.3 Requirement of the testing equipment

The voltage measurement device: 

not less than 0.5 grade

The current measurement device: 

not less than 0.5 grade

AC Impedance: 

1000 Hz

Temperature meter: 

precision ≤ 0.5°C 

The size measurement device: 

± 0.1% 

The quality measurement device: 

± 0.1%

5.4 Electrochemical characteristics

Unless otherwise specified, the cell should be fresh cell and tested by standard charge and discharge.

5.4.1

Rate discharge capability

(1)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C;

(2)  Discharge: 0.2C, 0.5C, 1C, 2C, 3C constant current discharge to cut-off voltage ≤ 2.5 V.

Current / Relative Capacity:

 0.2C / 100%, 0.5C / ≥96%, 1C / ≥93%, 2C / ≥90%, 3C / ≥88%

5.4.2

RT cycle life

(1)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C (32 mA);

(2)  Discharge: 1C constant current discharge to cut-off voltage ≤ 2.75V.

Discharge capacity of 801th cycle 

Original discharge capacity 

≥80%

(1)  Charge: 0.5C constant current charge to 4.15V followed by 4.15V constant voltage charge to cut-off current ≤ 0.05C (162 mA) 

(2)  Discharge: 1C constant current discharge to cut-off voltage ≤ 3.00V.

Discharge capacity of 1001th cycle 

Original discharge capacity 

≥80%

5.4.3

High-low temperature discharge performance

(1)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C at 25±2°C;

(2)  Discharge: 0.2C constant current discharge to cut-off voltage ≤ 2.5V at 25°C, 60°C, 45°C, 10°C, 0°C, -10°C, -20°C.

Temperature / Relative Capacity: 

25°C / 100%, 60°C / ≥95%, 45°C / ≥95%, 10°C / ≥88%, 0°C / ≥85%, -10°C / ≥75%, -20°C / ≥70%

5.4.4

Storage performance at 25°C (100% SOC)

(1)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C; Discharge: 0.2C 

constant current discharge to cut-off voltage ≤ 2.5V, to obtain the initial capacity;

(2)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C;

(3)  Stored at 25 ± 2°C for 28 days;

(4)  Discharge: 0.2C constant current discharge to cut-off voltage ≤ 2.5V, to obtain the residual capacity;

(5)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C; Discharge: 0.2C 

constant current discharge to cut-off voltage ≤ 2.5V, to obtain the recovery capacity.

Capacity / Relative Capacity:

 Residual capacity / ≥90%, Recovery capacity / ≥95%, Initial capacity / ≥100%

5.4.5

Storage performance at 60°C (100% SOC)

(1)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C at 25±2°C; Discharge: 

0.2C constant current discharge to cut-off voltage ≤ 2.5V at 25±2°C, to obtain the initial capacity;

(2)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C at 25±2°C;

(3)  Stored at 60 ± 2°C for 28 days;

(4)  Kept at 25 ± 2°C for 5 hours;

(5)  Discharge: 0.2C constant current discharge to cut-off voltage ≤ 2.5V at 25±2°C, to obtain the residual capacity;

(6)  Charge: 0.5C constant current charge to 4.2V followed by 4.2V constant voltage charge to cut-off current ≤ 0.01C at 25±2°C; Discharge: 

0.2C constant current discharge to cut-off voltage ≤ 2.5 V at 25±2°C, to obtain the recovery capacity.

Capacity / Relative Capacity:

 Residual capacity / ≥85%, Recovery capacity / ≥90%, Initial capacity / ≥100%