5.1 Battery charging, FIGURE 6.

The system has a 100-240Volt, 1.5A battery charger. The battery can be charged when installed in 

the P1004 unit or separately.

WARNING: The battery can only be charged with supplied battery charger 

(Part No.P-06 03 001).

All new units must be charged before they are used for the first time.

The charger must not be used in any circumstances for any other purpose than for which it was 

manufactured. It is intended for indoor use (must be protected from damp) and must not be used to 

charge non-rechargeable batteries.

The battery will be fully charged in about 3.5hours (also the heavy duty battery) this depends on 

residual capacity.

The red light goes on during battery charged and the light will turn green when it is full charged 

(FIGURE 7).

The battery will discharge during a long period in storage. For this reason, always re-charge the 

battery if it has been stored for more than 15 days. To achieve maximum power when the battery is 

new, or has been stored for more than 3 months, charge and discharge the battery at least twice, 

remove the battery out of the P1004 unit and store separately.

Points of attention:

1. Check that the mains supply voltage to the charger is correct.

2. Connect the battery charger to the wall socket.

3. Connect the battery charger to the battery.

 

Figure 6

 

Figure 7

Содержание RazorWeld RWX5OOO

Страница 1: ...MPORTANT NOTICE INITIAL BATTERY USE CHARGING INITIAL BATTERY USE CHARGING TO ACHIEVE MAXIMUM POWER WHEN THE BATTERY IS NEW TO ACHIEVE MAXIMUM POWER WHEN THE BATTERY IS NEW OR HAS BEEN STORED FOR MORE...

Страница 2: ...2...

Страница 3: ...your body We recommend RCD safety switch is used with this equipment to detect any leakage of current to earth Fumes and gases are dangerous Smoke and gas generated whilst welding or cutting can be ha...

Страница 4: ...as cylinders are normally part of the welding process be sur e to treat them carefully CYLINDERS can explode if damaged Protect gas cylinders from excessive heat mechanical shocks physical damage slag...

Страница 5: ...product is incorrectly used together with non approved parts or components NOTE Only the P1004 particle filter gas filter and pre filter can be used together with this system Filters from other manufa...

Страница 6: ...IF HEAD PROTECTION IS REQUIRED CONSULT YOUR SAFETY OFFICER 4 UNPACKING ASSEMBLY Check that correct number of components has been supplied as in FIGURE 1 Check that the apparatus is complete undamaged...

Страница 7: ...the blower unit through the two blower slots FIGURE 3 C Slide the fasten belt back into the waist connector FIGURE 3 D Put the release buckle back into the belt FIGURE 3 E Adjust the belt tightness so...

Страница 8: ...se replace it Carefully observe the instructions that explain how the equipment is to be used before taking it into service All components must be installed used in accordance with this manual if the...

Страница 9: ...battery will be fully charged in about 3 5hours also the heavy duty battery this depends on residual capacity The red light goes on during battery charged and the light will turn green when it is ful...

Страница 10: ...anged if the battery operating time becomes too short 5 2 Checking of airflow and checking of low airflow alarm The airflow and alarm system must always be checked before using 1 Test air flow The sys...

Страница 11: ...wn the faceseal ring and put on the head top Adjust the headgear to suitable tightness so that it will be stable on the head The tightness of headgear can be adjusted by pushing and turning of the adj...

Страница 12: ...m is working at level 2 Press the on button again The system is working at level 3 Press the on button again The system is working back to level 1 Press the off button for at least 3 seconds The PAPR...

Страница 13: ...Prefilter 4 P0402 Spark Arrestor 5 P0405 Blower unit 6 P0301 Li ION battery 7 P0601 Breathing tube 8 9 P0501 Waist belt Dual Straps 10 P0604 Portable airflow tester 11 P0603 Battery charger 12 P0503...

Страница 14: ...y WARNING Check the expiry date of the unopened filter DO NOT use it if it s expired Only the P1004 particle filter gas filter and pre filter can be used together with this system Filters from other m...

Страница 15: ...d Red light flashes Filter blocked Hose blocked Remove obstruction change the filter Clean hose LCD temperature icon flashes Warning sound Red light flashes High temperature Stop working and rest No f...

Страница 16: ...165 x 70 mm Weight 2 4KG Air Filter 1 P2 Air Flow Level 1 165L min Level 2 200L min Level 3 230L min Noise Level Max 73dB Operating Temperature 23 C to 131 C 5 C 55 C Storage temperature 14 C to 131...

Страница 17: ...od Alternatively and at it s discretion The company may replace This guarantee is subject to The P1004 unit has been used solely for the purpose for which it is intended The P1004 unit has not been su...

Страница 18: ...NOTES 18...

Страница 19: ...NOTES 19...

Страница 20: ...18 New Zealand Limited...

Отзывы: