Automatic voltage regulator (AVR)

This generator has been equipped with AVR technology 

which provides automatic voltage regulated power for a 

continuous uninterrupted stable power supply. 
The AVR maintains a regulated AC output and reacts 

substantially quicker to rapid surges in voltage, therefore, 

reducing the possibility of damage to the generator and 

attached equipment.
However, it is strongly suggested to use a surge protector 

on the output of the generator.
The generator is also not recommended to be used on 

electronic or sensitive equipment like computers, televisions 

and similar devices. This also includes caravans which have 

built in electronic inverter equipment.

What the Xceed 2300W generator is for:

•  

Lights 

•  

Hand tools

•  

Dryer 

•  

Fry pan

•   

Washing machine (non electronic)

• 

Small pumps up to 400W

• 

Small refrigerators (Non electronic)

• 

Power tools up to 600W

• 

Heaters up to 900W

• 

Pumps up to 1000W

• 

Large refrigerators up to 1000W

• 

Hand tools up to 1500W

• 

Stationary tools up to 1200W

• 

Heaters up to 2000W

• 

Household NON electronic appliances up to 2000W,   

ie. kettles, toasters

The Xceed 2300w generator is not recommended for use 

on sensitive electronic equipment including LCD / plasma 

televisions, computers, microwaves etc, and including 

caravans which have internal inverter controls.

It is also recommended to use a surge protector on the 

outlets of the generators.

Preparing the generator

It is important to check the generator before you commence 

operating the unit.

IMPORTANT.

 Ensure that the engine is fully filled with oil. 

When leaving the factory, this generator has NO OIL in  

the engine.

Note.

 The engine will not start if the generator has no oil  

or low oil.

Checking the engine fuel

1. Switch off engine by moving the ignition switch (12a or 

12b) to the ‘off’ or ‘O’ position.

2. Check the fuel level by viewing the fuel level gauge (3)  

or removing the fuel cap (2) to check. 

3. If the fuel is low, remove the fuel cap (2) by turning 

anticlockwise.

4. Check to ensure the fuel filter screen is inside the fuel 

filter neck.

5. Pour the unleaded fuel from an approved fuel container into 

the fuel tank (1). Because fuel expands, DO NOT FILL to 

the lip of the tank. Max. fill is to the top of the fuel filter rim.

6. Replace fuel cap (2) and turn clockwise to lock.

WARNING.

  Do not refill fuel tank (1) while engine is running or is hot.

  Check to ensure that the fuel drain (16) has been 

tightened and that fuel is not leaking.

  Be careful not to admit dust, dirt, water or other foreign 

objects into the fuel.

  Wipe off spilt fuel thoroughly before starting engine.

  Ensure you DO NOT fuel the generator in close proximity 

to any open flames, lit cigarettes, or hot objects.

  The generator should also be located in an open area 

with fresh air and NOT in a confined area.

Содержание X2300KS

Страница 1: ...INSTRUCTION MANUAL X2300KS 254 2173 2300W PETROL GENERATOR...

Страница 2: ...utlet 20 To use the DC appliance outlet or USB without the generator being operated 21 DC overload cut out 21 Carbon build up 22 Generator maintenance 22 Periodic maintenance 23 Storage 24 Spark plugs...

Страница 3: ...ax 5 A USB output 5V Max 1 Amp Motor 5 5HP 4 stroke No load speed 3000 min 1 Fuel tank capacity 15L Fuel type Unleaded Oil type 4 Stroke Net weight 38 5kg Electric start Yes Items required for operati...

Страница 4: ...ntangled cords increase the risk of electric shock When operating a power tool outdoors use an outdoor extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk o...

Страница 5: ...in the hands of untrained users Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged...

Страница 6: ...charge conductive surfaces in contact with the generator Place generator on low conductivity surface such as a concrete slab ALWAYS operate generator a minimum of 2 meters from any conductive surface...

Страница 7: ...ngine speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the en...

Страница 8: ...rator in clean dry well ventilated area Never operate unit in enclosed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away...

Страница 9: ...ng operation These parts are covered by guarding to prevent injury Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewellery which could be caught...

Страница 10: ...ce Ensure the generator has oil Before commencing the generator ensure that the unit has been filled with SAE 30 4 stroke oil Never fill fuel tank indoors Never fill fuel tank when engine is running o...

Страница 11: ...tery charging socket 10 DC appliance socket 11 USB power outlet 12 Electric start key start 13 Air filter cover 14 Choke lever 15 Spark plug 16 Fuel drain 17 Muffler 18 Exhaust spark arrestor 19 DC pl...

Страница 12: ...nverter controls It is also recommended to use a surge protector on the outlets of the generators Preparing the generator It is important to check the generator before you commence operating the unit...

Страница 13: ...check the oil level each time the generator is used Battery start connection When unpacked this generator is not fully connected to the starting battery 22 and will require the negative wire to be co...

Страница 14: ...on Fig G Note When the motor is started for the very first time it may require a number of attempts to start until the fuel has travelled from the tank to the motor 5 Once you hear the motor operating...

Страница 15: ...nerator 2 Turn the key start ignition 12 to the OFF position Fig J1 3 Turn the fuel lever anti clockwise to the off position Connecting apparatus to the generator Start the generator and allow the gen...

Страница 16: ...of a some failed appliances and assisting to protect people against an electric shock Safety switch tripping If the circuit breaker 4 has tripped and cuts off the power it may be due to substantial o...

Страница 17: ...e button to reset Note The 12V appliance socket can also be used with the 240V AC outlets being used To use the battery charging outlet The generator is fitted with a socket outlet specifically for co...

Страница 18: ...if the battery was originally in a low level of charge the battery will take many hours to recharge fully The time frame will depend on the size of the battery As a guide a standard car battery of aro...

Страница 19: ...the Appliance plug connected to the appliance socket in the generator is fitted with a fuse Using the lead acid car battery as the power source the following ratings should not be exceeded 12V applian...

Страница 20: ...used for 4 hours run the generator for 1 hour at around 75 of rating This is only required if the generator has been used for less than 50 or rated load If the generator is being used for solely char...

Страница 21: ...ace if necessary Valve clearance Check and adjust when engine is cold Fuel line Check fuel hose for crack or damage Replace if necessary Exhaust system Check for leakage Retighten or replace gasket if...

Страница 22: ...K RN11YC Champion WR6DC Bosch Model G1100KU W7RBC Bosch RL87BC Champion BPR7HS NGK Engine oil replacement 1 Place the generator on a level surface and warm up the engine for several minutes The stop t...

Страница 23: ...ter 24 prevents any dirt in the fuel from entering the fuel system The procedure for removing this filter in order to replace or clean it is given below Note the following procedure should be performe...

Страница 24: ...here are no leaks between the tap and the tank and with the fuel tap turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap Cleaning 1 Keep your machine clean The o...

Страница 25: ...en fuel shut off valve 7 Unit loaded during start up 7 Remove load from unit 8 Spark plug wire loose 8 Attach wire to spark plug No electrical output 1 Faulty receptacle 1 Have service centre replace...

Страница 26: ...loaded 1 Reduce load 2 Insufficient ventilation 2 Move to adequate supply of fresh air No DC Output 1 DC circuit overloaded 1a Remove DC load and reset cut out after 5 min 1b If Battery charging check...

Страница 27: ......