background image

20

5. When re connecting appliances, reduce the load to that 

which previously overloaded the generator.

Note.

 The output of the DC from the generator is regulated 

to a maximum of 5A.
If an appliance requires more than 5A to operate, the voltage 

will reduce and the appliance will run less than 100% or will 

not operate at all.
If 10A is required, it can be achieved by connecting a 

separate battery to the battery charging socket and following 

the steps in the section, 

“ To use the DC appliance outlet 

or USB outlet without the generator being operated”

 

(Page 18).

Carbon build up

Carbon build up can be a problem on generators as the 

loading on the motor can vary considerably.
Carbon build up in the motor can be reduced by operating 

the generator at approx. 75% of rated load  for 25% of the 

time the generator is used. ie, if the generator is used for 4 

hours, run the generator for 1 hour at around 75% of rating. 

This is only required if the generator has been used for less 

than 50% or rated load.

If the generator is being used for solely charging a battery, 

it is recommended to run the 240Vac at around 500W for 

the generators up to 2000W and 1000W for the generators 

between 2000 and 5500W if the charging cycle will be run 

for many hours. When Charging is complete, try and run the 

generator at around 75% of  rated load for  an hour or so.
Use unleaded fuel without ethanol. 

Generator maintenance

Your generator should be kept clean and dry at all times. The 

generator should not be stored or operated in environments 

that includes excessive moisture, dust or any corrosive 

vapours. If these substances are on the generator, clean with 

a cloth or soft bristle brush. Do not use a garden hose or 

anything with water pressure to clean the generator. Water 

may enter the cooling air slots and could possibly damage the 

rotor, stator and the internal windings of the generator head.

Содержание X2300KS

Страница 1: ...INSTRUCTION MANUAL X2300KS 254 2173 2300W PETROL GENERATOR...

Страница 2: ...utlet 20 To use the DC appliance outlet or USB without the generator being operated 21 DC overload cut out 21 Carbon build up 22 Generator maintenance 22 Periodic maintenance 23 Storage 24 Spark plugs...

Страница 3: ...ax 5 A USB output 5V Max 1 Amp Motor 5 5HP 4 stroke No load speed 3000 min 1 Fuel tank capacity 15L Fuel type Unleaded Oil type 4 Stroke Net weight 38 5kg Electric start Yes Items required for operati...

Страница 4: ...ntangled cords increase the risk of electric shock When operating a power tool outdoors use an outdoor extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk o...

Страница 5: ...in the hands of untrained users Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged...

Страница 6: ...charge conductive surfaces in contact with the generator Place generator on low conductivity surface such as a concrete slab ALWAYS operate generator a minimum of 2 meters from any conductive surface...

Страница 7: ...ngine speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the en...

Страница 8: ...rator in clean dry well ventilated area Never operate unit in enclosed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away...

Страница 9: ...ng operation These parts are covered by guarding to prevent injury Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewellery which could be caught...

Страница 10: ...ce Ensure the generator has oil Before commencing the generator ensure that the unit has been filled with SAE 30 4 stroke oil Never fill fuel tank indoors Never fill fuel tank when engine is running o...

Страница 11: ...tery charging socket 10 DC appliance socket 11 USB power outlet 12 Electric start key start 13 Air filter cover 14 Choke lever 15 Spark plug 16 Fuel drain 17 Muffler 18 Exhaust spark arrestor 19 DC pl...

Страница 12: ...nverter controls It is also recommended to use a surge protector on the outlets of the generators Preparing the generator It is important to check the generator before you commence operating the unit...

Страница 13: ...check the oil level each time the generator is used Battery start connection When unpacked this generator is not fully connected to the starting battery 22 and will require the negative wire to be co...

Страница 14: ...on Fig G Note When the motor is started for the very first time it may require a number of attempts to start until the fuel has travelled from the tank to the motor 5 Once you hear the motor operating...

Страница 15: ...nerator 2 Turn the key start ignition 12 to the OFF position Fig J1 3 Turn the fuel lever anti clockwise to the off position Connecting apparatus to the generator Start the generator and allow the gen...

Страница 16: ...of a some failed appliances and assisting to protect people against an electric shock Safety switch tripping If the circuit breaker 4 has tripped and cuts off the power it may be due to substantial o...

Страница 17: ...e button to reset Note The 12V appliance socket can also be used with the 240V AC outlets being used To use the battery charging outlet The generator is fitted with a socket outlet specifically for co...

Страница 18: ...if the battery was originally in a low level of charge the battery will take many hours to recharge fully The time frame will depend on the size of the battery As a guide a standard car battery of aro...

Страница 19: ...the Appliance plug connected to the appliance socket in the generator is fitted with a fuse Using the lead acid car battery as the power source the following ratings should not be exceeded 12V applian...

Страница 20: ...used for 4 hours run the generator for 1 hour at around 75 of rating This is only required if the generator has been used for less than 50 or rated load If the generator is being used for solely char...

Страница 21: ...ace if necessary Valve clearance Check and adjust when engine is cold Fuel line Check fuel hose for crack or damage Replace if necessary Exhaust system Check for leakage Retighten or replace gasket if...

Страница 22: ...K RN11YC Champion WR6DC Bosch Model G1100KU W7RBC Bosch RL87BC Champion BPR7HS NGK Engine oil replacement 1 Place the generator on a level surface and warm up the engine for several minutes The stop t...

Страница 23: ...ter 24 prevents any dirt in the fuel from entering the fuel system The procedure for removing this filter in order to replace or clean it is given below Note the following procedure should be performe...

Страница 24: ...here are no leaks between the tap and the tank and with the fuel tap turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap Cleaning 1 Keep your machine clean The o...

Страница 25: ...en fuel shut off valve 7 Unit loaded during start up 7 Remove load from unit 8 Spark plug wire loose 8 Attach wire to spark plug No electrical output 1 Faulty receptacle 1 Have service centre replace...

Страница 26: ...loaded 1 Reduce load 2 Insufficient ventilation 2 Move to adequate supply of fresh air No DC Output 1 DC circuit overloaded 1a Remove DC load and reset cut out after 5 min 1b If Battery charging check...

Страница 27: ......

Отзывы: