background image

ensure that the receptacle cord is 

positioned so that the face is per

-

pendicular to the floor as in Figure 

4.

 CAUTION:

 For continued pro

-

tection against risk of fire, replace 

only with same type and rating of 

fuse, 10 amp fuse maximum.

5.

The receptacle is intended for

plugging in a heater

 

(supplied 

with the mantel),

 

which will 

allow the heater to

 

be 

controlled with the provided

 

remote. (Figure 4

CAUTION: 

The receptacle

cord is intended for use only with 

the heater 6909070159. If this 

receptacle is used with any other 

product, 

Xaralyn

 will not be liable 

for any damage or issues 

that 

may arise.

 Installation

15A 120V

Plug

10A 120V

Receptacle

Figure 4

9

Transducer

Rock 
Media

Removable Refill 

 

Container

Light Bulbs

 Assembly

Figure 5

1.

Carefully unpack all of the

components from the box.

(Figure 5)

2.

Remove top cover by turning

the retaining tabs on both ends

of the water reservoir. (Figure

6)

3.

Install the light bulbs by

aligning the pins on the bulbs 

and the fixture and pressing 

down until they are fully 

inserted. (Figure 7)

4.

Install the transducer so that

it is sitting level in the circular

holding area in the reservoir.

5.

Orient transducer wire so that

it does not sit directly above

the emitter and the wire passes

through the slot in the side of

the tank. (Figure 6)

6.

Reinstall the top cover and

ensure both retaining tabs have

been turned so that they are

pointing inwards.

7.

Fill and install the Refill

Container.

!

NOTE:  

Normal tap water can

be used in the Optimyst

®

 as long

as the tap water is not considered

to be hard water.  In the event your

tap water is hard, you may use soft

-

ened water or distilled water with

1/8 tsp of salt (0.5 mL) added to the

water reservoir.  (The addition of

additional salt should only be used

when you notice that the unit is not

producing mist as expected.)

!

NOTE: 

During initial installation,

the Refill Container should be 

refilled after the Reservoir has filled 

to ensure the maximum operating 

time.

Remote 
Control

Log Media

Housing

Media 
Tray

Содержание Optimyst

Страница 1: ...NFORMATION Always read this manual first before attempting to install or use the Optimyst cassette For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage ...

Страница 2: ... SAFETY INSTRUCTIONS 4 Installation 6 Assembly 9 Operation 11 Maintenance 13 Warranty 15 Replacement Parts 17 3 Welcome Congratulations Thank you and congratulations for choosing to purchase an Optimyst cassette Please carefully read and save these instructions CAUTION Read all instructions and warnings carefully before starting installation Failure to follow these instructions may result in a pos...

Страница 3: ... gaso line paint or flammable liquids are used or stored Do not modify the unit Use it 5 SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons To reduce the risk of electric shock this appliance has a three pronged plug This plug will fit in a grounded outlet only o...

Страница 4: ...nishing NOTE A 15 Amp 120 Volt cir cuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis when the cassette is operating Additional appliances on the same circuit may exceed the current rating of the circuit breaker Mantel Installation Install the fireplac...

Страница 5: ...e 6 3 Install the light bulbs by aligning the pins on the bulbs and the fixture and pressing down until they are fully inserted Figure 7 4 Install the transducer so that it is sitting level in the circular holding area in the reservoir 5 Orient transducer wire so that it does not sit directly above the emitter and the wire passes through the slot in the side of the tank Figure 6 6 Reinstall the to...

Страница 6: ...p of the unit below the control cover Figure 8 A On Off Switch Supplies power to the cassette B Mode Selector Switch Press once to turn on the flame effect This will be indicated by an audible beep Although the lights turn on immediately it will take 30 seconds before the flame effect starts Press again to give flame effect and heat This will be indicated by two beeps Press again to return to flam...

Страница 7: ... tenance or cleaning to reduce the risk of fire electric shock or damage to persons Filling the water tank When the water tank is empty the flame shuts off and you will hear 2 audible beeps follow these steps CAUTION Allow at least five minutes for components to cool be fore disassembling the unit to refill 1 Turn the On Off switch to the off position 0 Figure 8 2 Gently remove the media tray and ...

Страница 8: ...d war ranty Products purchased in Yukon Territory Nunavut Northwest Territories Hawaii or Alaska are not covered by this limited war ranty Products purchased in these States provinces or territories are sold AS IS without warranty or condition of any kind including without limitation any implied warranties or conditions of merchant ability or fitness for a particular purpose and the entire risk of...

Страница 9: ...EN IF XARALYN OR ITS DIRECTORS OFFICERS OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES COSTS OR DAMAGES OR IF SUCH LOSSES COSTS OR DAMAGES ARE FORESEEABLE IN NO EVENT WILL XARALYN OR ITS OFFICERS DIRECTORS OR AGENTS BE LIABLE FOR ANY DIRECT LOSSES COSTS OR DAMAGES THAT EXCEED THE PUR CHASE PRICE OF THE PRODUCT SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL...

Страница 10: ......

Отзывы: