step 

7

. This section uses the knobs to set the 

CV value present at the CV output for each step 
and uses the buttons to activate/deactivate 
each respective step. An active step generates 
signal at the 
gate  out output 

8

. Note that 

the cv out always sends the voltage set for each 
step, regardless of whether the step is active.

Moskwa is equipped with three inputs situated 
at the bottom left of the panel that allow for re-
al-time playback interaction. The 
transport 
input 

9

 

pauses the sequence (see: “Global Set-

tings” section), the reset input 

10

 

resets the 

sequence  to  the  first  step,  and  the  direction 
input 

11

 

reverses the direction of the sequence.

At the top of the panel, there are three smaller 
knobs and three buttons. The 
rand play knob 

12

 gradually mutates the sequence resulting in 

some steps being randomly replaced by other 
steps from the same sequence. Turning the knob 
clockwise increases the probability of replacing 
the next step with another step chosen random-
ly and returning the knob to 0 returns the se-
quence to the current panel settings. The 
slew 
knob 

13

 

sets the global slew time from zero up 

to the length of a whole step. The probability 
knob 

14

 increases the probability of random 

setting inversions (activated by steps  2-4 in 
the 
step mode, see: “Step Settings” section). The 
value set by the potentiometer is common for 
all the steps, but for each step, the draw is per-
formed individually, so the result can be differ-
ent for each step. The 
custom/shift button 

15

 

activates a custom sequence (see: “Custom Se-
quence” section below), and also acts as a shift 
control giving access to secondary functions. 
The 
step/quant button 

16

 

chooses the step 

mode (single press), or the quantization menu 
(press and hold). The 
patt/preset button 

17

 

activates the pattern  mode (single press), or 
the preset manager (press and hold).

front panel 

overview

2

6

9

12

15

10

1

Содержание Moskwa II

Страница 1: ...MOSKWA roto sequencer ii Model of 1965 operator s manual rev 1965 2 0...

Страница 2: ...al clock which allows for syn chronization with other modules in the system The incoming clock rate can be internally divided or multiplied In addition to these basic functions Moskwa II offers more u...

Страница 3: ...he entire manual before use PANEL OVERVIEW Moskwa s panel is divided into four function al sections with a row of inputs outputs at the bottom of the module In the center is the transport button 1 sur...

Страница 4: ...er steps from the same sequence Turning the knob clockwise increases the probability of replacing the next step with another step chosen random ly and returning the knob to 0 returns the se quence to...

Страница 5: ...5 fig 2 interface 13 8 14 4 5 16 17 7 3 11...

Страница 6: ...h step button will be illumi nated red or orange and the sequence step will last either one clock cycle or up to eight clock cycles for details see below Remember if the given step is inactive even an...

Страница 7: ...t To avoid unexpect ed pitch jumps after touching a knob the value changes only when you move the knob past the value written with the preset To recall the cur rent knob positions load an empty preset...

Страница 8: ...e is audible yet Hold the step 1 8 button for one second to enter edit mode To edit multiple pat terns at the same time press and hold the first pattern button and then push the others to be edited Th...

Страница 9: ...self creating sequence of inversions of settings activated with step 2 4 buttons in the step mode see Step Settings The sequence consists of 16 steps it changes ev ery two main sequencer cycles The pr...

Страница 10: ...activate step press transport step 1 8 to clear indiv step settings press step 1 8 to select scale 1 chromatic 2 major 3 minor 4 pentatonic major 5 pentatonic minor 6 akebono 7 arabian 8 phrygian clea...

Страница 11: ...behaves likewise Therefore the users have at their disposal two longer se quences eachwithuniquesettings notonlyquan tization and range but also e g the slew time The sequence length depends on the r...

Страница 12: ...RT IF SOMETHING WENT WRONG WITH A XAOC PRODUCT AFTER THE WARRANTY PERIOD IS OVER NO NEED TO WORRY AS WE RE STILL HAPPY TO HELP THIS APPLIES TO ANY DEVICE WHEREVER AND WHENEVER ORIGINALLY ACQUIRED HOWE...