SPC
I Co
mmand T
ree
975-0200
-01-01
A-29
A
Set Operation
Status
Shutdown
Protection
Positive
Transition
Register
[:]STATus[<channel>]:OPERation
:SHUTdown:PROTection:PTRansition
Access the Operation
Shutdown Protection
Positive Trans Filter
Register.
See Table 5-12 on page 5–
35.
?|<Transition Flags
- (0–65535)>
Yes
Query
Operation
Status Event
Register
[:]STATus[<channel>]:OPERation
:CSHare[:EVENt]?
Query the Operations Event
Register.
See Table 5-11 on page 5–
34.
Yes
Set Operation
Status Enable
Register
[:]STATus[<channel>]:OPERation
:CSHare:ENABle
Access the Operations
Enable Register. See
Table 5-11 on page 5–34.
?|<Transition Flags
- (0–65535)>
Yes
Query
Operation
Status
Condition
Register
[:]STATus[<channel>]:OPERation
:CSHare:CONDition?
Query the Operations
Condition Register. See
Table 5-11 on page 5–34.
Yes
Set Operation
Status
Positive
Transition
Register
[:]STATus[<channel>]:OPERation
:CSHare:PTRansition
Access the Operation
Positive Trans Filter
Register. SeeTable 5-11 on
page 5–34.
?|<Transition Flags
- (0–65535)>
Yes
Set Operation
Status
Negative
Transition
Register
[:]STATus[<channel>]:OPERation
:CSHare:NTRansition
Access the Operation
Negative Trans Filter
Register. See Table 5-11 on
page 5–34.
?|<Transition Flags
- (0–65535)>
Yes
Table A-10
Status Commands (Continued)
Содержание XTR6-110, XTR8-100, XTR12-70,
Страница 2: ......
Страница 3: ...XTR 850 Watt and 1700 Watt Series Programmable DC Power Supply Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 48: ...2 18...
Страница 86: ...Local Operation 3 38 975 0200 01 01 Figure 3 4 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 122: ...4 30...
Страница 208: ...6 20...
Страница 244: ...A 36...
Страница 250: ...B 6...
Страница 264: ...C 14...
Страница 272: ...IX 4...
Страница 273: ......