Troubleshooting

6

975-0271-01-01

Troubleshooting

Understanding Error Codes

If the products connected to PowerSource 1800 do not operate and the alarm is sounding, check PowerSource 1800 LED screen for an error code.

Troubleshooting Reference

Error

Possible Cause

Solution

E01

Low voltage shutdown because battery is discharged.

Recharge battery by plugging the AC power cord into a wall outlet.

E03

Overload shutdown while supplying backup power. The AC product(s) 
connected are consuming more than PowerSource 1800’s power rating.

The AC products connected have a surge power that exceeds 
PowerSource 1800 surge capability.

One or more of the connected products are damaged.

Use products with a total power consumption within PowerSource 1800’s continuous power rating of 
1440 W.

Use products with a total starting surge power within PowerSource 1800’s capability of 2880 W.

Have the damaged product serviced by a qualified technician.

E04

Over-temperature shutdown has occurred. PowerSource 1800 has 
overheated due to poor ventilation, excessive ambient temperature, or 
power demand beyond the unit’s output power capability.

Disconnect products from the AC outlets. Allow the unit to cool for 20 minutes. Clear blocked fan or 
remove objects covering unit. Move the unit to a cooler place. Reduce load to less than 1800 W if 
continuous operation is required.

E05

Under-voltage warning. The battery is nearly discharged.

Reduce the load to extend run time during backup mode. Assuming the AC power cord was unplugged 
and the unit turned to backup mode, when utility power is present or becomes available, recharge the 
battery by plugging the AC power cord into a wall outlet.

E06

Over-temperature warning. PowerSource 1800 is overheating due to poor 
ventilation, excessive ambient temperature, or high power demand.

Reduce the load to avoid over-temperature shutdown, clear blocked fan or remove objects covering unit, 
or move the unit to a cooler place.

Problem

Problem/Symptom

Solution

PowerSource 1800 will 
not turn on.

Battery is discharged and utility power is 
not available at the wall outlet.

Ensure power is available at the wall outlet.

No power available at the 
120 VAC outlets.

AC outlet has been overloaded or the 
supplementary protector has tripped.

Reduce the number of products plugged into the AC outlets. Check the supplementary protector at the back of the 
unit. If necessary, reset the breaker by pushing it fully inward.

AC utility is not available 
and products connected to 
unit lose power. 

PowerSource 1800 has detected an 
overload condition.

PowerSource 1800 has detected an over-
temperature condition.

PowerSource 1800 has exhausted its 
available battery power.

PowerSource 1800 may require service.

Make sure the products plugged into 

the

 AC outlets are not exceeding the output power rating of the unit when 

supplying backup power. Try removing or substituting some of the products.

Disconnect products from the AC outlets. Make sure the products plugged into the AC outlets are not overloading the 
continuous output power rating of the unit when supplying backup power. Allow the unit to cool, increasing 
ventilation if necessary. If the unit is left on, it restarts automatically when the unit cools down.

PowerSource 1800 shuts down when all available battery power has been used. Allow the unit to recharge for 
15 hours before continuing to use the unit.

Contact Xantrex Technical Support for further troubleshooting (see “Contact Information” on page 1).

Products connected to unit 
malfunction or overheat.

Products connected to PowerSource 1800 
do not accept modified sine wave form.

Your application is not compatible with PowerSource 1800 modified sine wave output. See “Precautions for Using 
Rechargeable Appliances” on page 2.

Inadequate run time.

PowerSource 1800 battery is not fully 
charged.
Battery is near the end of its useful life.

PowerSource 1800 has turned off.

Charge the battery by leaving PowerSource 1800 plugged into a wall outlet at least 15 hours.

As the battery ages, the available run time decreases. The internal battery also ages prematurely if PowerSource 1800 
is installed in a hot environment or not kept in a charged condition. See “Battery Replacement” on page 5.

Press for at least half a second to turn unit on.

Содержание xpower PowerSource 1800

Страница 1: ...S HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION THE ACCURACY CANNOT BE GUARANTEED APPROVED XANTREX CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT www xantrex com Date and Revision September 2007 Revision B Part Number 975 0271 01 01 Product Number 852 1802 Contact Information IMPORTANT SAFETY INSTRUCTIONS Operating the XPower PowerSource 1800 incorrectly or...

Страница 2: ... heat including space heaters and pellet stove igniters Visit www xantrex com for higher power solutions Precautions for Using Rechargeable Appliances Most rechargeable battery operated equipment uses a separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output Some chargers for rechargeable batteries can be damaged if connected to the PowerSou...

Страница 3: ...internal battery 4 LED Screen indicates charging status power draw from the PowerSource 1800 W when providing backup power or battery capacity The screen also shows error codes to aid troubleshooting 5 Select Button displays PowerSource 1800 Battery Level or Output Power W 6 Charged Charging LED green illuminates when PowerSource 1800 is fully recharged and flashes while PowerSource 1800 is rechar...

Страница 4: ...d the unit for optimal ventilation Important When connected to utility power the unit automatically provides AC power from its internal battery when the utility voltage falls below 105 VAC Condition LED status Alarm status Alarm stops sounding when Normal operation Utility power is available and unit is turned on The internal battery is fully charged AC Power LED and Charged Charging LED are solid...

Страница 5: ...each the end of their service life and if you choose not to have a qualified technician replace them the PowerSource 1800 itself is no longer of use The internal batteries may be replaced following the guidelines in Battery Replacement above Because the internal batteries contain lead which can be hazardous to the environment the batteries and the PowerSource 1800 should be recycled or safely disp...

Страница 6: ...is discharged and utility power is not available at the wall outlet Ensure power is available at the wall outlet No power available at the 120 VAC outlets AC outlet has been overloaded or the supplementary protector has tripped Reduce the number of products plugged into the AC outlets Check the supplementary protector at the back of the unit If necessary reset the breaker by pushing it fully inwar...

Страница 7: ...ler is unable to provide service contact Xantrex directly at What proof of purchase is required In any warranty claim dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex Proof of purchase may be in any one of the following forms The dated purchase receipt from the original purchase of the prod...

Страница 8: ...MAGES LOSSES COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND ANY LOSS OR DAMAGE TO PROPERTY ANY PERSONAL INJURY ANY DAMAGE OR INJURY ARISING FROM OR AS A RESULT OF MISUSE OR ABUSE OR THE INCORRECT INSTALLATION INTEGRATION OR OPERATION OF THE PRODUCT Exclusions If this product is a consumer product federal law does not allo...

Отзывы: