Charging Voltage Setpoints
36
XPLORE 120/12 Battery Charger Owner's Guide
Charging Voltage Setpoints
The XPLORE Charger charging process is designed to make the
battery or battery banks reach the following voltage setpoints.
Battery Type
Absorption
(Volts)
Float
(Volts)
Equalization
(Volts)
Flooded
14.4
13.5
16.0
GEL
14.2
13.8
not
applicable
AGM
14.3
13.4
not
applicable
LiFePO
4
14.6
13.4
not
applicable
Custom
14.4
(default,
changeable)
13.4
(default,
changeable)
not
applicable
Table 5 Charging Maximum Voltages
Battery Qualification
The XPLORE Charger will perform a battery qualification on each
application of AC (or DC > 9 V), to determine if battery banks are
present and healthy.
To force a battery detection sequence,
1. Turn off AC (mains) and DC power sources.
2. Wait approximately 20 s or until all lights on the charger or
remote have gone out.
3. Turn on DC.
4. Turn on AC.
The charger will then perform a battery detection.
Temperature Considerations
The optional Battery Temperature Sensor (BTS) protects your
battery and improves charging accuracy. Attach the BTS to the
warmest battery.
If no BTS is connected, the charger defaults to 25 °C (77 °F).
Содержание XPLORE 120A 12V
Страница 1: ...XPLORE 120A 12V Battery Charger Owner s Guide Model XPLORE 120 12 Battery Charger 819 0120 12...
Страница 12: ...This page is intentionally left blank 2...
Страница 18: ...This page is intentionally left blank 2...
Страница 24: ...This page is intentionally left blank 2...
Страница 60: ...This page is intentionally left blank 2...
Страница 72: ...975 1038 01 01 Rev C 31021 http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...