Environmental Specifications
975-0402-01-01
A–5
This guide for use by qualified installers only
Environmental Specifications
Absorption voltage:
±0.1 V for 12 Vdc units
±0.2 V for 24 Vdc units
12 Vdc units
24 Vdc units
25 °C (77 °F)
25 °C (77 °F)
Flooded 14.4 28.8
GEL 14.2
28.4
AGM 14.3
28.6
Lead-calcium
15.5
31.0
Float voltage:
±0.1 V for 12 Vdc units
±0.2 V for 24 Vdc units
12 Vdc units
24 Vdc units
25 °C (77 °F)
25 °C (77 °F)
Flooded 13.5
27.0
GEL 13.8
27.6
AGM 13.4
26.8
Lead-calcium
13.5
27.0
Equalize mode current
50% rated output ±6%
Equalize mode—maximum
output voltage
12 V units: 16 ±0.1 Vdc
24 V units: 32 ±0.2 Vdc
Off-state current draw
(without remote installed)
12 V units: <35 mA dc
24 V units: <20 mA dc
Voltage regulation
Uncompensated load voltage regulation
< 0.1Vdc drop from 0 Amps to rated current
output at charger output terminals (adds in
series with recommended 3% limit for user's
battery cable voltage drop).
Operating range
(full performance)
0 – 50 °C (32 – 122 °F)
Current de-rating (above 50 °C
ambient temperature)
up to 80% derating Imax
50 – 65 °C (122 – 149 °F)
Storage
–40 to 80 °C (–40 to 176 °F)
Humidity
5 – 95%, RH non-condensing