Faults Display & Reset Button
20
Prosine 2.5/3.0 Installation & Operation Guide
Faults Display & Reset Button
Fault LED
This LED flashes on-and-off during an error
condition from which the unit will automatically recover and
restart when the condition is remedied. The
FAULT
LED will
be lighted steadily when any error occurs from which the
inverter/charger cannot automatically recover. It is usually
necessary to disconnect the AC or DC supply to recover from
this type of error. An error condition is accompanied by an
audible alarm if the alarm is enabled. All error messages, their meanings, and the appropriate action to
take are listed in a table in
Temp LED
This LED flashes on-and-off to indicate excessive internal temperature of the Prosine
inverter/charger and the unit has shutdown. When the internal temperature of the unit cools
sufficiently, the inverter/charger will automatically restart. The audible alarm that accompanies this
condition (if enabled) will also be silenced upon auto-restart.
Reset Button
The
RESET
button on the Faults panel has two functions: silencing the audible
alarm; and displaying error codes. Pressed and released, it will silence the audible alarm which, if
enabled, will sound an irritating intermittent tone anytime an error condition occurs. Pressed and held,
the RESET button causes the LCD screen to display error codes.
Inverter Status Indicators and On/Off Button
Invert LED
When the green
INVERT
LED is flashing,
shorepower is not present, Load Sense is enabled, and no
AC loads exceed the Load Sense threshold. The inverter is
not producing AC power from the batteries. When the
Invert
LED is lighted steadily, shorepower is not present
and the inverter is producing AC power from the batteries.
The
INVERT
LED is not lighted when shorepower is present.
Standby LED
When the amber LED labeled
STANDBY
is lighted steadily, shorepower is present
and the inverter will pass AC power through to any AC loads that may be present.
If shorepower should fail or be removed while the inverter is in Standby mode, the inverter will
automatically begin to produce AC power from the batteries, and the
INVERT
LED will be lighted.
ON/OFF Button
When pressed, this button switches the inverter from On to Standby mode.
Содержание Prosine PS2.5 and
Страница 1: ...Xantrex ProsineTM 2 5 and 3 0 Inverter Chargers Installation and Operation Guide PS2 5 PS3 0...
Страница 2: ...ProsineTM PS2 5 Inverter Charger PS3 0 Inverter Charger Installation and Operation Guide...
Страница 9: ...vi Prosine 2 5 3 0 Installation Operation Guide Figure 1 Inverter Charger Components...
Страница 13: ...Return Procedure x Prosine 2 5 3 0 Installation Operation Guide...
Страница 21: ...Inverter Features 4 Prosine 2 5 3 0 Installation Operation Guide...
Страница 41: ...Battery Temperature Sensor 24 Prosine 2 5 3 0 Installation Operation Guide...
Страница 75: ...Operating Limits for Inverter Operation 58 Prosine 2 5 3 0 Installation Operation Guide...
Страница 83: ...Operating Limits for Charger Operation 66 Prosine 2 5 3 0 Installation Operation Guide...
Страница 95: ...Cabling Hook up Configurations 78 Prosine 2 5 3 0 Installation Operation Guide...
Страница 98: ...Prosine 2 5 3 0 Installation Operation Guide 81 Appendix A Specifications Prosine 2 5 3 0 Chassis Dimensions...
Страница 99: ...82 Prosine 2 5 3 0 Installation Operation Guide Prosine 2 5 3 0 Chassis Dimensions with Brackets...
Страница 101: ...84 Prosine 2 5 3 0 Installation Operation Guide...
Страница 111: ...Error Code Table 94 Prosine 2 5 3 0 Installation Operation Guide...