16
Mobile 100 automatically shuts down. After
shutdown, the unit beeps twice and the status
LED flashes twice.
•
Appliances such as televisions and devices with
motors consume much more power than their
average rating when they are turned on. Although
the PowerSource Mobile 100 can briefly supply
surge power of up to 160 W, some devices may
exceed its surge capability and shut down the
inverter.
•
If the PowerSource Mobile 100 exceeds a safe
operating temperature due to insufficient
ventilation or a high-temperature environment, the
PowerSource Mobile 100 beeps and the status
LED flashes every two seconds as a warning. If
the temperature continues to climb, the
PowerSource Mobile 100 automatically shuts
down. After shutdown, the unit beeps twice and
the status LED flashes twice.
•
If a defective battery charging system causes the
battery voltage to rise to dangerously high levels,
the PowerSource Mobile 100 automatically shuts
down. After shutdown, the unit beeps twice and
the status LED flashes twice.
XP_Powersource_Mobile_100.book Page 16 Wednesday, August 16, 2006 11:29 AM