Battery Charger Specifications
975-0289-01-01
A–5
Charging Profiles
40-amp Charging Profile
Table A-5 provides the specific charging parameters for the 40 Charging
Profile.
Table A-5
40-amp Charging Profile
Parameter Name
Default Value
Charger Setting
40 A
Maximum Bypass Current
500 W (4 A)
Bulk Mode
40 A
Absorption Mode
14.2 Vdc (4 hours maximum)
Float Mode
13.7 Vdc (8 hours)
Switches from Absorption to Float
Mode
4 A
Switches from Float Mode back to
Bulk Mode within the 8-hour limit,
if the Float current increases to
6 A.
6 A
Standby Mode (Off Mode)
12.5 Vdc
Estimated charging time
8 hours based on a single battery box with
two 100 Ah, 12 Vdc batteries and no
other DC charging sources