1.0 INTRODUCTION
Controls and Indicators
Indicator LEDs
Three LEDs located on the front panel of the GSM indicate the relay
control signal status from the inverter.
NOTE: The LEDs are unaffected by the GSMs switch positions or
fuse condition.
GENERATOR RUN/GLOWSTOP RELAY 7 LED
The yellow LED indicates relay RY7 is receiving a control signal to
engage the relay and RUN the generator or provide a GLOWSTOP signal
(for diesel generators). The LED turns ON when the relays COM and N.O.
contacts engage. The function of this relay is dependent on the selection
made (using the SWRC) as to whether it is used to RUN the generator or
provide GLOWSTOP control.
GENERATOR START RELAY 8 LED
The green LED indicates relay RY8 is receiving a START signal from the
inverter. The LED turns ON when the relays COM and N.O. contacts
engage.
INVERTER OPERATIONAL LED
The blue LED indicates the inverters operational status. If the inverter is
powered and ready for operation, the blue SYSTEM OPERATIONAL LED
turns ON as soon as the phone-type cable is plugged into the inverter. If
the blue LED does not turn ON, the inverter is either not powered, is set to
the CHG only mode without any utility pass-through, or has no AC output
which may be caused by an error condition.
Figure 2
Indicator LEDs
Yellow LED
RUN/GLOWSTOP
RELAY 7
Green LED
GENERATOR START
RELAY 8
Blue LED
INVERTER OPERATIONAL
OFF = INVERTER ERROR