Operating Limits
78
Freedom X 1200 Owner's Guide
Operating
Condition
Battery
Voltage
Comment
High
Voltage
Shutdown
16.7 V
The display shows error code
E02
alternating with the battery
voltage. The red status LED
turns on.
NOTE:
Although the Freedom X
1200 incorporates over-voltage
protection, it can still be
damaged if input voltage
exceeds 16.7 V
Z
.
Overload Conditions
There are two kinds of overload conditions – an overload warning
and an overload shutdown.
Overload
Warning
When the Freedom X 1200’s AC load is approximately
100 W below the overload shutdown limit of rated watts,
the audible alarm beeps once and the LCD screen
shows a warning code
E06
.
Overload
Shutdown
When the Freedom X 1200’s AC load increases to near
~1300 W, the audible alarm beeps every five seconds
for one minute and the LCD screen shows a error code
E03
. The Status LED turns solid RED.