Basic Installation Procedures
42
Freedom X 1200 Owner's Guide
Step 5: Connecting AC Output to an
Existing AC Circuit
WARNING
ELECTRIC SHOCK AND FIRE HAZARDS
n
Make sure wiring is disconnected from all electrical sources
before handling. All wiring must be done in accordance with
local and national electrical wiring codes.
n
A manufacturer-tested and approved GFCI must be
connected to the Freedom X 1200 AC output, and GFCI
protection must be provided on every receptacle connected
to the AC hard wired installation. Other types may fail to
operate properly when connected to the Freedom X 1200.
See
Ground Fault Circuit Interrupters (GFCIs) on page 33
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
NOTICE
EQUIPMENT DAMAGE
n
Do not connect any AC source (such as a generator or
utility power) to the
AC output wiring
of the Freedom X
1200.
n
The Freedom X 1200 will not operate if its output is
connected to AC voltage from a source, and potentially
hazardous or damaging conditions may occur. These
conditions can occur even if the inverter is off.
Failure to follow these instructions can result in equipment
damage.
Do not connect the Freedom X 1200 to an AC branch circuit that
has high-power consumption loads that exceed its output wattage
rating.
The Freedom X 1200 will not operate electric heaters, air
conditioners, stoves, and other electrical appliances that
consume more than its rated output wattage.