Freedom Sequence Intelligent Power Manager Owner’s Guide
Basic Configuration Settings
Restore Defaults
Freedom Sequence stores different profiles in its memory:
Factory
,
OEM
,
and
User
. Each profile can store an entirely different configuration for
Freedom Sequence and its AC/DC Relays.
By default, the
OEM
and
User
profiles have settings that are the same as the
Factory
profile.
Upon start-up of Freedom Sequence, the
User
profile is used as the active
profile to perform the AC and DC load-shedding functions. If settings are
changed on the active profile, they automatically get copied to the
User
profile. If by mistake, a wrong setting is configured, all basic and advanced
settings can be restored to their OEM settings via
Restore Defaults
from
the
Config
screen on the SCP. The
OEM
profile can only be accessed and
modified via the XDT tool.
To restore to OEM defaults, the
Mode
must be first changed to
Standby
.
To
Restore Defaults
from the Device
Status
screen:
FSPM 00: Status
L2 Amps
Batt Voltage
Circuit Status
Config
On 0.0A
12.8V
FSPM 00: Config
SHR BKR Mode
SHR BKR Rating
Circuit Config
Restore Defaults
[Manual]
[30.0A]
3
Press to
scroll down.
4
Press to
restore default
settings.
1
Press to
scroll down.
2
Press to select
Config
.