4. Mount and install the DC wiring components including the battery disconnect switch

(if applicable), fuseholders, and the busbars. Their relative locations are shown in the
system diagram. The battery disconnect switch and the fuseholder for the main
battery fuse should be located as close to the BMS positive terminal as possible. If
applicable, install the fuseholder for the DC load branch fuse on the positive cable
close to the positive DC busbar.

5. Mount and install the second alternator using the tools and instructions provided in

the alternator kit. Follow the steps below as a guide but refer to the manufacturer’s
instructions for complete detail.

a. Install the second alternator using the mounting bracket and pulley provided in

the alternator kit.

b. Ensure the alternator chassis is securely fastened to the vehicle metal chassis.

c. Use a straight edge or laser alignment tool to ensure pulleys are within 0.5

degrees of alignment.

d. Check all pulley grooves to ensure they are clean and undamaged. Check the

belt to make sure there are no visible cracks, splits, or defects before installing
it.

e. Install the belt. Ensure the belt is properly seated in the pulley grooves.

f. Check the belt tension between the engine and second alternator according to

the manufacturer’s recommendations. Adjust accordingly using the provided
tensioner and a tension gauge. Under or over-tensioned belt will cause belt
slippage and premature belt failure. It can also result in overheating of the
alternator leading to equipment damage.

5.

g. Check that the Balmar Regulator has the “LFP” sticker before mounting. Contact

Xantrex if the “LFP” sticker is missing.

h. Mount the Balmar Regulator.

i. Follow the second alternator manufacturer's wiring instructions and use the

wiring harness in the alternator kit to make the connections between the second
alternator and the Balmar Regulator.

j. Make sure the alternator temperature sensor in the wiring harness is installed

on the second alternator’s chassis and connected to the correct pins on the
Balmar Regulator to prevent equipment damage and fire.

k. Make DC cable connections at the alternator. Refer to “DC Cable and Fuse

Requirements” for conductor sizing. Use a separate cable for alternator
negative return to the battery. Ensure all electrical connections are secured. To
protect from dust and water, install a skid plate (not provided but
recommended).

6. Read “DC Cable and Fuse Requirements”. Then, make the DC cable connections

between all system devices by following the “System Diagram for Power Connection”.
Observe correct polarity.

7. Install the required DC fuses on to their respective fuseholders.

8. If applicable, install a venting tube (rubber tubing) to the pressure balancing valve on

the battery and secure it with a clamp.

9. Make AC wiring connections to the Freedom XC PRO Inverter/Charger according to

the “System Diagram for Power Connection”. Follow the Freedom XC PRO
Inverter/Charger installation guide (document number: 975-0099-01-01) for AC wire
sizing instructions.

a. Wire the Freedom XC PRO Inverter/Charger AC OUTPUT to your AC load

panel.

b. Ensure that all upstream and downstream surge protector and AC circuit

breakers and downstream GFCIs are properly installed. Refer to the Freedom
XC PRO Inverter/Charger installation guide for breaker sizes.

10. Make the system communication connections between all system devices using the

provided system wiring harness (881-0042-12). Use the labels on the wiring harness
as a guide and follow the “System Diagram for Communication Connection”. Follow
the vehicle manufacturer’s instructions when wiring to the vehicle’s ignition circuit.

11. End devices in the CANbus network must both be terminated with a 120Ω resistor.

12. Ensure the installation complies with regional, national, and local electrical codes.

13. Make sure all DC and AC connections are secure. Install and put on all necessary

safeguard and covers. Make sure there are no exposed conductors. Remove LOTO.

14. Perform the end-of-line functional check (document number: 976-0361-01-01). Make

sure that the Battery Type is set to

LFP

.

3

System Devices

Device Name

Part Number

Freedom XC PRO 2000 | 3000 Inverter/Charger

818-2010

818-3010

Ford Transit Alternator Kit (option 1)

882-0050-12

Sprinter 6-cylinder Alternator Kit (option 2)

882-0010-12

Sprinter 4-cylinder Alternator Kit (option 3)

882-0020-012

Dodge Promaster Alternator Kit (option 4)

882-0030-12

Xantrex Battery 12V 600Ah (option 1)

880-0600-12

Xantrex Battery 12V 450Ah (option 2)

880-0450-12

Xantrex Battery 12V 630Ah (option 3)

880-0630-12

Xantrex Battery Management System

881-0406-12

Battery Disconnect Switch (12VDC, 450A min)

--

Use one of UL-listed fuses

-- Class T fuse rated 350A, 125VDC

-- Class J fuse rated 400A, 450VDC

-- Class J fuse rated 450A, 450VDC

c

 Use of other fuses and

fuseholders voids the UL
listing of the system.

NOTE

: Class J fuses are

only permitted with the
12V 630Ah battery

Fuse holder must be UL Listed (IZLT), suitable for single-pole, Type J
or Type T fuses, rated 600V, 450A

System Wiring Harness

881-0042-12

Table 1 Required eGEN system devices and components

Device Name

Part Number

Skid Plate for the second alternator

--

100A fuse, Littelfuse [Required if the system includes the
Xantrex Battery Combiner (PN: 881-0030-12)]

MEG100

600A Busbars,1 for pos(+) and 1 for neg(-), Blue Sea

2104

Busbar cover, Blue Sea

2708

Xantrex Battery Combiner

881-0030-12

12A Temperature Sensor Switch

Heating Blanket, eGEN 135W (sold together)

881-0240-12

881-0060-12

100W Xantrex Solar Kit / 100W Expansion Kit

780-0100-01 / 780-0100-02

160W Xantrex Solar Kit / 160W Expansion Kit

780-0160-01 / 780-0160-02

110W Xantrex Solar Flex Kit / 110W Expansion Kit

781-0100-01 / 781-0100-02

Xantrex Solar 30A PWM Charge Controller

709-3024-01

Xantrex Solar 30A MPPT Charge Controller

710-3024-01

Freedom X Remote Panel (Bluetooth)

808-0817-02

Freedom XC PRO Communications Harness

881-0820

System Remote Panel including LCD Display

881-0401-12

Table 2 Recommended eGEN system devices and components

4

Installation

WARNING

HAZARD OF ELECTRIC SHOCK, FIRE, OR PERSONAL INJURY

Read the system installation guide and associated product manuals prior to installation.

Failure to follow these instructions can result in death or serious injury.

1. Prior to installation, identify and isolate all energy sources from the system. De-

energize the system by:

a. removing AC power

b. turning off vehicle ignition

c. turning off the BMS

Keep the system de-energed throughout the installation process.

Follow all necessary safety precautions, use personal protective equipment (PPE) and
perform lock-out, tag-out (LOTO).

2. Plan the mounting locations for all the devices and wiring components prior to wiring.

Follow the mounting instructions for each device, verify the weight-bearing capacity of
each mounting location and orientation, and ensure sufficient clearance for proper air
ventilation.

3. Mount and install the system devices before making cable or wiring connections.

Secure heavy objects such as the inverter and the battery by bolting/strapping them to
the floor.

Содержание Freedom e-GEN

Страница 1: ...nt is well ventilated In case of fire use only a Class ABC type dry chemical fire extinguisher Water can be a dangerous extinguishing medium for energized equipment because of the risk of electrical shock Dispose of Xantrex Batteries through a local recycling center Do not mix batteries with other wastes Contact your local recycling center for proper disposal information Failure to follow these in...

Страница 2: ...zes 10 Make the system communication connections between all system devices using the provided system wiring harness 881 0042 12 Use the labels on the wiring harness as a guide and follow the System Diagram for Communication Connection Follow the vehicle manufacturer s instructions when wiring to the vehicle s ignition circuit 11 End devices in the CANbus network must both be terminated with a 120...

Страница 3: ... 4 0 Chassis battery 90 2 cable is from the Device to the DC busbar free air 30 C ambient Table 3 Minimum system DC cable size requirements l Use DC cables with a higher insulation temperature rating 105 C if possible However a higher insulation temperature rating does not mean the conductor size can be reduced due to the temperature ratings of the terminal connections Always use a qualified insta...

Страница 4: ...ion purposes only Always use a professional installer that satisfies the requirements for a qualified personnel Failure to follow these instructions can result in damage to equipment NOTE The diagram is for information and illustration purposes only Images are not to scale The system diagram is not intended to guide the actual placement of equipment Read and follow DC Cable and Fuse Requirements s...

Страница 5: ...C BLADE System Diagram for Communication Connection EQUIPMENT DAMAGE The system diagram is for information and illustration purposes only Always use a professional installer that satisfies the requirements for a qualified personnel Failure to follow these instructions can result in damage to equipment NOTE The diagram is for information and illustration purposes only Images are not to scale Route ...

Отзывы: