![Xantrex ACCB Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/xantrex/accb/accb_owners-manual_3176465040.webp)
Installation
1–28
975-0046-01-01
To make the neutral connections:
1. Create only one neutral-to-ground bond in the system. In this case, it
would be in the
ACCB
.
2. Connect the factory-installed neutral wire (white) in the
ACCB
to the
NEU2 terminal in the inverter.
3. Connect the neutral (white) wire from the generator (or generator
disconnect) and connect it to one of the neutral terminals in the
ACCB.
4. Route and connect a neutral wire from one of the neutral connections
in the ACCB to the outlet that will support the AC load.
Important:
Ensure there is only one neutral-to-ground bond in the entire
system. See the Sine Wave Plus Inverter/Charger Owner’s Manual for additional
information regarding the neutral-to-ground bond requirements.
Figure 1-24
Neutral Connections for an Off-grid Application with Additional Circuit
Breakers in the ACCB