Deutsch Connector Pin Designations
975-1044-01-01
17
Communication Installation
This section contains instructions for other functions that can be
used in vehicle systems providing additional performance and
usage scenarios. These functions need to be connected through
the 12-Pin Deutsch connector. This sections contains the
following topics:
Deutsch Connector Pin Designations
Deutsch Connector Pin
Designations
The pins should only be connected to devices on an as-needed
basis. The Xantrex Battery will function without having the
communication ports externally connected to the battery.
The Deutsch connector harness is available using product code
(PN: 881-0262-12-02). Contact Xantrex or your Xantrex dealer
to order.
Figure 11 Deutsch connector harness
7
12
6
1
NOTICE
EQUIPMENT DAMAGE
Incorrect wiring and pin assignments may lead to equipment
malfunction and/or damage.
Failure to follow these instructions can result in equipment
damage.
Pin #
Color
Function
Signal
12 or 24 V
nominal
according to
model
Feature Description
1
Red
Engine Running
Input
Input High
(12/24V)
• Turn the battery from OFF to ON state.
• If the internal contactor is closed then it shall wait two
seconds before Pin 2 shall go high. (If the signal to Pin 1
is removed, Pin 2 shall also drop immediately.)
2
Orange Alternator
Activation Output
(FCC Enable)
Output
High
(12/24V)
If the internal contactor is closed and the battery pack
needs to open it (due to a fault), the BMS will set the
Alternator Activation output low (0V) to turn off the
alternator, wait two seconds, and then open the internal
contactor.
3
Grey
Push button wire 1
out (power)
Signal
(12V,
10mA)
Push Button wire 1 (momentary switch)
c
This wire is to be utilized for the Remote Push-button
Supply ONLY.
4
Grey
Push button wire 2
in (return)
Return
Push button wire 2 (momentary switch)
Power on this pin for certain times and sequences can
perform the following actions:
• Power the Unit ON
• Power the Unit OFF
• Enter Maintenance Mode
• Clear Faults
• Other Maintenance Features.
5
Black
LED output
Output
(12/24V)
On/Off LED output
6
Black
LED return
Return
Common return for remote on/off LEDs
7
White CAN High
COMM
CAN/RV-C High
8
Blue
CAN Low
COMM
CAN/RV-C Low
9
Black
Low SOC
alarm / Intelligent
Generator Start
Output
(12/24V)
Low SOC alarm:
This pin will pulse a high signal for one (1) second every
twenty (20) seconds when the battery 21% > SOC
>11%. The pin will pulse for one (1) second every five
(5) seconds when the battery SOC = 11%. The pin will
be held high when the SOC < 10%.
Intelligent Generator Start:
The intelligent generator start option is only configurable
using the SOC gauge (881-0268-01). Default operation is
when the battery SOC < 20% the signal shall go high
until the SOC >80% of the battery. These thresholds can
be changed using the SOC display.
Table 1 Pin reference guide