NOTICE
REVERSE POLARITY DAMAGE
Check cable polarity before making the final DC connection. Positive must be connected to positive;
negative must be connected to negative. Reversing the positive and negative battery cables may damage
the battery and void your warranty.
Failure to followthese instructions can result in death, serious injury, orequipment damage.
8. Attach the pos(+) battery cable to the fused battery cable.
NOTE
: When attaching more than one lug to each terminal, make sure at least 1/4” or
6mm of thread is available to secure the connection. Additionally, the ring terminal
lugs need to be “clocked” in such a way that they do not interfere with their flat
conducting surfaces. Acquire and use longer M8x1.25mm terminal bolts if necessary.
9. Turn the battery on and verify the voltage on the DC bus.