Operating Limits
58
Freedom X 2000 - 230V Owner's Guide
High Surge Loads
Some induction motors used in freezers, pumps, and other motor-
operated equipment require high surge currents to start. The
Freedom X may not be able to start some of these motors even
though their rated steady state current draw is within the inverter’s
limits. The unit will shut down and indicate an overload shutdown.
Over-temperature Conditions
During inverter operation, when the Freedom X’s internal
temperature starts to approach its preset shutdown limit, the
display will show error code
E07
. If the over-temperature condition
persists, the display will show error code
E04
. The Status LED
turns solid RED and the inverter will shut down to prevent damage
to the inverter and protect the battery from being over-discharged.