975-0390-01-01
45
Specifications
NOTE
: These specifications refer to charger mode.
AC Input
1000-watt models
1500 and 1800-watt models
Operating voltage range for all models
90–130 VAC
90–130 VAC
Operating voltage range for Freedom HF 1500
and Freedom HF 1800 T
5 AAC at 20 A charge, 120 VAC IN
10 AAC at 40 A charge, 120 VAC IN
Nominal current
5 AAC at 20 A charge, 120 VAC IN
10 AAC at 40 A charge, 120 VAC IN
Nominal frequency
60 Hz
60 Hz
DC Output
1000-watt models
1500 and 1800-watt models
Nominal voltage
12.0 VDC
12.0 VDC
Min battery voltage for charging
0.0 VDC
0.0 VDC
Max output voltage
14.4 VDC
14.4 VDC
Nominal output current
User selectable:
2A, 5A, 10A, 20A (Freedom HF 1000)
5A, 15A, 35A, 55A (Freedom HF 1055)
User selectable:
2A, 10A, 20A, 40A
Charger current derating
Charger current will automatically derate as
internal temperature exceeds 80 °C.
Charger current will automatically derate as
internal temperature exceeds 80 °C.
Efficiency at nominal output
75%
75%
Other
1000-watt models
1500 and 1800-watt models
No load input power (producing output voltage)
10W
10W
Off mode current draw
1mA
1mA
Regulatory Approvals
1000-watt models
1500 and 1800-watt models
ETL approved to CSA 107.1, UL458, and UL458 Marine Supplement (drip shield with product
number 808-9531 required).
Freedom HF InvChg Owners Guide.book Page 45 Wednesday, September 13, 2017 6:20 PM
Содержание 806-1020
Страница 2: ...Freedom HF InvChg Owners Guide book Page ii Wednesday September 13 2017 6 20 PM...
Страница 12: ...Freedom HF InvChg Owners Guide book Page x Wednesday September 13 2017 6 20 PM...
Страница 14: ...Freedom HF InvChg Owners Guide book Page ii Wednesday September 13 2017 6 20 PM...
Страница 60: ...Freedom HF InvChg Owners Guide book Page 46 Wednesday September 13 2017 6 20 PM...
Страница 61: ...Freedom HF InvChg Owners Guide book Page i Wednesday September 13 2017 6 20 PM...