background image

  

Upgrade 

Mode 

 

 Chapter 8                                                               53 

C

C

h

h

a

a

p

p

t

t

e

e

r

r

 

 

8

8

:

:

 

 

U

U

P

P

G

G

R

R

A

A

D

D

I

I

N

N

G

G

 

 

T

T

H

H

E

E

 

 

X

X

T

T

R

R

A

A

L

L

I

I

N

N

K

K

 

 

I

I

P

P

 

 

 

 

F

F

I

I

R

R

M

M

W

W

A

A

R

R

E

E

 

 

New 

XTRALINK IP

 firmware updates may become available through 

the Xantech website (www.xantech.com) for installation into the 
server. The firmware can be uploaded using either a virtual COM port 
connection or hardware COM port connection. 

Downloading the Firmware 

Make a folder to receive the firmware file. Download the compressed 
software file from the Xantech website (www.xantech.com). Unzip or 
expand the file into the (.hex) format so it will be ready to upload to the 

XTRALINK IP

Upgrading Via XTRALINK IP IPRS23202 Manager 

The 

XTRALINK IP IPRS23202 Manager

 software can upload new 

firmware to the server using a direct PC connection via the 
XTRALINK IP serial port or using a virtual COM port.  

N

N

o

o

t

t

e

e

:

:

 

 

 

 If connecting directly to a computer serial port, use a null modem 
cable between the Computer RS-232 port and the XTRALINK IP serial 

port or  Port 1. 

Preparing the Software 

Step 1:

 In the 

XTRALINK IP IPRS23202 Manager

 

XTRALINK IP List

 

window, double click the server to be upgraded. The 

Server 

Properties

 window will appear.  

Step 2:

 If using a direct connection to upload the firmware to the 

XTRALINK IP

, set the baud rate to 

115200

 for the fastest 

possible upload.  

Step 3:

 Set the 

Serial Port

 field to upgrade and click the 

Update

 

button. (Ensure that the DIP switches on the XTRALINK IP 
are all in the OFF position.) 

Step 4:

 Click 

Yes

 on the 

vcomui

 dialogue to restart the 

XTRALINK IP

 Upgrade 

Mode 

54                                                                      Chapter 8 

 

Upgrading the Firmware 

Step 5:

  Double-click the 

Firmware Upgrade

 icon (or click the 

Server

 

menu and 

Firmware Upgrade

Step 6:

  In  the 

Upgrade 

window, click 

Browse

. The 

Open

 dialogue 

box will appear. Locate the folder on your PC that contains the 
firmware .hex file. 

Select

 the file and click 

Open

. The Open 

dialogue box will disappear. 

Step 7:

 In the 

Upgrade

 window select the serial port to be used in 

transferring the firmware.  

a.  If connected directly from the PC to a 

XTRALINK IP 

 

port it will typically be COM1 or COM2 

b.  If using a virtual COM

 

port to upgrade via the 

network, identify the virtual COM number and 
address mapped to Port 1 on the 

XTRALINK IP

Step 8:

  Click 

Upgrade

  

Step 9:

 In the 

Port Settings

 window set the 

Bits per second

Data 

bits

Parity

 and 

Stop

 bits to the same values as set up in the 

Server Properties 

window. Click 

OK. 

 

 

Figure 50.  The Port Settings Window 

Step 10:

 Upgrade progress

 will be shown until the 

Upgrade finished! 

message is shown. Click 

OK

Содержание XTRALINK IP

Страница 1: ...Second Floor Sylmar CA 91342 3573 Sales 800 843 5465 Fax 818 362 9506 X XT TR RA AL LI IN NK K I IP P M Mu ul lt ti i I In nt te er rf fa ac ce e E Et th he er rn ne et t X XT TR RA AL LI IN NK K I I...

Страница 2: ...100 Telfair Avenue Second Floor Sylmar CA 91342 3573 Sales 800 843 5465 Fax 818 362 9506 Xantech Corporation 13100 Telfair Avenue Second Floor Sylmar CA 91342 3573 Sales 800 843 5465 Fax 818 362 9506...

Страница 3: ...notice and does not represent a commitment on the part of Xantech Corporation Xantech shall not be liable for incidental or consequential damages resulting from the furnishing performance or use of t...

Страница 4: ...WARE 17 SOFTWARE INSTALLATION 17 Automatic Installation 17 Manual Installation 17 ii Table of Contents Updating an Existing Installation 19 Opening the XTRALINK IP IPRS23202 Manager 20 CHAPTER 4 USING...

Страница 5: ...SETTING SERVER PROPERTIES 59 CHAPTER 11 USING TELNET 62 CONFIGURATION USING TELNET 62 Navigating the Configuration Menu 64 CHAPTER 12 XTRALINK IP AND TECHNICAL DATA 66 APPENDIX A RS 232 CONNECTIONS 70...

Страница 6: ...gure 34 The Restart Dialogue Box 38 Figure 35 The Restarting Dialogue Box 39 Figure 36 The Server Search Dialogue Box 39 Figure 37 The Search XTRALINK IP IPRS23202 MANAGER Dialogue Box 39 Figure 38 Co...

Страница 7: ...iguration via the network using any web browser o Telnet allows configuration via the network by accessing the setup configuration menu o Console Mode allows configuration through an RS 232 serial por...

Страница 8: ...either TCP server or UDP server with a designated communication port number The virtual COM driver is the TCP or UDP client Paired Mode Paired Mode is also called serial tunneling In this mode any two...

Страница 9: ...INK IP IPRS23202 Manager software It will automatically search for any reachable XTRALINK IP DEVICES A list of all XTRALINK IP connected to the LAN will appear in the XTRALINK IP List window Step 2 Do...

Страница 10: ...ocol and the appropriate IP address determined in the last section Figure 4 Configuring the Virtual COM Port Check Communications Step 1 From the Windows Start menu run HyperTerminal Step 2 Configure...

Страница 11: ...ector DB 9M Indicator Lights Light Indication Power Red power is applied Link Yellow 10BaseT Ethernet connection established Green 100BaseTX Ethernet connection established Ready Flashing Green system...

Страница 12: ...as HyperTerminal When the XTRALINK IP enters Console Mode the Console Mode screen will appear in the HyperTerminal program window The serial port settings must be 8 N 1 at 9600 baud 12 Chapter 2 Figur...

Страница 13: ...t to the XTRALINK IP serial port or Serial Port 1 Upgrading also can be accomplished via the network connection using the XTRALINK IP IPRS23202 Manager software and a virtual COM port N No ot te e Ref...

Страница 14: ...xantech com 16 Chapter 2 XTRALINK IP Serial Port Connector Pin outs Pin outs for RS 232 RS 422 and RS 485 operation are shown below DB 9M Pin RS 232 Signal Name DTE RS 422 RS 485 1 Carrier Detect DCD...

Страница 15: ...Uninstall Virtual COM Ports Automatic Installation Step 1a Inserting the CD in the CD ROM should automatically launch the Install Shield Wizard Manual Installation Step 1b To manually start the softw...

Страница 16: ...e Opening the XTRALINK IP IPRS23202 Manager Step 5 If the XTRALINK IP is not already connected to the network or to the Ethernet port on the computer connect it Set all the DIP switches to the OFF pos...

Страница 17: ...puter Ethernet port Set all the DIP switches on the XTRALINK IP to the OFF position Figure 19 Ethernet Connection via a LAN USING XTRALINK IP IPRS23202 MANAGER 22 Chapter 4 Figure 20 Direct Ethernet C...

Страница 18: ...ort o Serial TX Displays the number of bytes of data sent to the serial device since the IP connection was established o Serial RX Displays the number of bytes of data received from the connected seri...

Страница 19: ...to each XTRALINK IP port IP Address Displays the IP Address for the XTRALINK IP All ports in a XTRALINK IP have the same IP address Protocol Displays the currently selected TCP or UDP mode for the XTR...

Страница 20: ...erties Window USING XTRALINK IP IPRS23202 MANAGER 28 Chapter 4 N No ot te e XTRALINK IP IPRS23202 Manager Navigation Use the mouse to select the property and parameters or Tab to move to the next prop...

Страница 21: ...RS23202 MANAGER Dialogue Box After that port has been updated you may want to re enter Server Properties to verify the changes have taken effect or to view change the configuration of other ports Each...

Страница 22: ...NK IP A new Server Name of up to 16 characters can be entered If more than one XTRALINK IP is connected on the LAN it is recommended that a new name be assigned to each When the XTRALINK IP IPRS23202...

Страница 23: ...window enter Ping xxx xxx xxx xxx IP address for the server to be confirmed The command will return the Ping results indicating 4 replies Figure 31 Pinging using the DOS command window Server Propert...

Страница 24: ...no value is entered into this field the server will not disconnect Connection Mode The Connection Mode field has three options Server Client and Client no heartbeat When Client or Client no heartbeat...

Страница 25: ...l port on the server RS 422 When this mode is selected and the server updated the selected serial port will become an RS 422 serial port on the server RS 485 When this mode is selected and the server...

Страница 26: ...een by tabbing through the list of screens on the left side of the window and highlighting Configuration Server Properties Configuration 40 Chapter 5 There are four options shown on the right side of...

Страница 27: ...erties Configuration Chapter 5 41 Figure 38 The Web Server Page N No ot te e If you leave any Web Server page without saving any changes you have made will be ignored Server Properties Configuration 4...

Страница 28: ...s which allows the software to open a connection with the serial port located anywhere on the LAN WAN When using the virtual COM port the XTRALINK IP is configured as a TCP or UDP Server Virtual COM P...

Страница 29: ...if used by the application program and serial hardware The XTRALINK IP must be set to match Installing Virtual COM Port 46 Chapter 6 Matching the XTRALINK IP and Virtual COM Port Settings The setting...

Страница 30: ...Click the Configuration or Port Settings tab This screen allows the settings to be changed if necessary Click Cancel to keep the existing settings Step 5 Click OK to change the settings Use Refresh in...

Страница 31: ...indows Desktop click Start Programs Xantech XTRALINK IP IPRS23202 MANAGER Servers XTRALINK IP IPRS23202 Manager Step 2 In the XTRALINK IP IPRS23202 Manager window click the Virtual COM List tab Highli...

Страница 32: ...ce Manager Window Step 4 Highlight XTRALINK IP IPRS23202 MANAGER COM to be removed and click the Action tab at the top of window then click Uninstall A confirm Device Removal window will appear Removi...

Страница 33: ...indow will appear Step 2 If using a direct connection to upload the firmware to the XTRALINK IP set the baud rate to 115200 for the fastest possible upload Step 3 Set the Serial Port field to upgrade...

Страница 34: ...232 crossover null modem cable Step 3 In the HyperTerminal Port Settings window set o Baud rate 9600 o Data bits 8 o Parity None o Stop bits 1 o Flow control None Click OK Step 4 Ensure all the DIP s...

Страница 35: ...e Configuration The restart message will appear Step 6 Select Yes to save changes This is necessary to write the settings to the server Using a Password If a password is used it must be entered before...

Страница 36: ...plorer type the IP Address of the XTRALINK IP into the address field near the top of the window and press the Enter key The following window will appear Figure 53 The Web Server Page Using the Web Ser...

Страница 37: ...plays the same configuration information shown in Console Mode and allows server properties to be configured N No ot te e See Chapter 5 for details on Server Properties Configuration Using Telnet Step...

Страница 38: ...le mode and the Server screen will appear Using Telnet 64 Chapter 11 Navigating the Configuration Menu There are six Telnet screens Server Network Serial Mode Operation Monitor and Configuration Tab B...

Страница 39: ...LINK IP module Power Supply 12 VDC 500mA tip positive sleeve negative Power Plug Area Dependent North America 120VAC 60Hz Europe United Kingdom 220 240VAC 50Hz Manual Paper copy of this manual PDF ava...

Страница 40: ...ulation XTRALINK IP IPRS23202 Manager Using Windows 98 ME 2000 XP or NT software Web Server Using a standard web browser such as Internet Explorer RS 232 Connections 68 Default Server Settings Server...

Страница 41: ...TI IO ON NS S XTRALINK IP DB 9 Pin outs in RS 232 Mode RS 232 Signal Name DTE RS 232 DB 9M Pin Carrier Detect In DCD 1 Receive Data In RXD 2 Transmit Data Out TXD 3 Data Terminal Ready Out DTR 4 Signa...

Страница 42: ...ct CD 1 1 CD Receive Data RD 2 2 RD Transmit Data TD 3 3 TD Data Terminal Ready DTR 4 4 DTR Signal Ground Common GND 5 5 GND Data Set Ready DSR 6 6 DSR Request to Send RTS 7 7 RTS Clear to Send CTS 8...

Страница 43: ...ttings The CD connection is needed by some terminal programs to simulate Carrier RS 422 Connections 74 A AP PP PE EN ND DI IX X B B R RS S 4 42 22 2 C CO ON NN NE EC CT TI IO ON NS S XTRALINK IP DB 9...

Страница 44: ...vides a common mode reference for the RS 422 Receiver and Transmitters N No ot te e The RS 422 mode can be used for full duplex 4 wire RS 485 operation provided that the XTRALINK IP is acting as a sol...

Страница 45: ...In Out DATA A 4 Signal Ground GND 5 Figure 71 DB 9 Pin out in RS 485 Mode N No ot te e Some RS 485 devices are marked opposite the RS 485 standard which defines the Data B line as positive relative to...

Страница 46: ...lue 4 5 Not used White Blue 5 6 RX Orange 6 7 Not used White Brown 7 8 Not used Brown 8 Figure 73 Pin out for a Standard Ethernet Cable Network Connections 80 Appendix D Crossover Ethernet Cable RJ 45...

Страница 47: ...81 Xantech Corporation 13100 Telfair Avenue Second Floor Sylmar CA 91342 3573 Sales 800 843 5465 Fax 818 362 9506 Xantech September 2004 Part No 08900795 Rev A 82...

Отзывы: