background image

3

Speakers & Volume Controls

WHEN USING 8 OHM SPEAKERS

Number of Speaker Pairs Used

S1

S1

1    2     3    4    5    6     7    8    9   10  11   12  13   14  15  16

S2

S2

S4

S4

S4

S4

S8

S8

S8

S8

S8

S8

S8

S8

S1

S2

S4

S4

S8

S8

S8

S8

Min. Amp.
Impedance

4 Ohms

8 Ohms

WHEN USING 4 OHM SPEAKERS

Number of Speaker Pairs Used

Min. Amp.
Impedance

S1

S2

1    2     3    4    5    6     7    8

S4

S4

S8

S8

S8

S8

S2

S4

S8

S8

4 Ohms

8 Ohms

SETTING THE IMPEDANCE MATCHING JUMPERS

The impedance matching jumpers are located under a clear mylar cover on the right side of the top of the
unit.  Remove the two screws for access.  The proper placement of these jumpers depends on the number
of RAT1's and speakers used in the total installation.  To set them for the best impedance matching
condition, refer to the following charts and procedures:

Procedure for all 4 Ohm or all 8 Ohm Speakers

1. Determine the rated speaker impedance (refer to the manufacturer's specifications - it must be the

same for all speakers used in the system).

2. Determine the total number of stereo speaker pairs used in the installation.

3. Determine the minimum safe amplifier operating load impedance (refer to the manufacturer's

specifications).

4. Find the correct jumper position from the above charts.

5. Place the jumpers in the same position on each RAT1 used in the system.

Example 1:

13 pairs of 8 Ohm wall speakers are to be used with 13 RAT1's in a 13 room system, all driven by one
amplifier rated for 4 Ohms minimum safe operating load impedance.

1. Refer to the chart "WHEN USING 8 OHM SPEAKERS".

2. Locate the number 13 in the top row.

3. On the next row, opposite "4 OHMS" and  just below "13", note the letters "S8".  These signify the

required impedance multiplier.

4. The two jumpers therefore, one for each channel, need to be plugged onto the S8 pins on each RAT1

that feeds each room.

Example 2:

3 pairs of 4 Ohm wall speakers are to be used with 3 RAT1's in a 3 room system, all driven by one amplifier
rated for 8 Ohms minimum safe operating load impedance.

1. Refer to the chart "WHEN USING 4 OHM SPEAKERS".

2. Locate the number 3 in the top row.

3. On the third row, opposite "8 OHMS" and just below "3", note the letters "S8".  These signify the

required impedance multiplier.

4. The two jumpers therefore, one for each channel, need to be plugged onto the S8 pins on each RAT1

that feeds each room.

RAT1

Содержание RAT 1

Страница 1: ...lug in connector IR STATUS 12V 4 screw plug in connector STATUS Input Jack 2 1mm coaxial type POWER Input Jack 12V 2 1mm coaxial type Power Consumption 300 mA 12V DC Use Xantech Model 786 00 or 782 00...

Страница 2: ...use APPLICABLE RC68 BUTTON DESCRIPTIONS 1 IR Emitter Lens 2 Instant Volume Presets These buttons allow direct preset activation of any of the 10 volume steps on the RAT1 Useful for audio scene ambian...

Страница 3: ...rmine the minimum safe amplifier operating load impedance refer to the manufacturer s specifications 4 Find the correct jumper position from the above charts 5 Place the jumpers in the same position o...

Страница 4: ...inimum safe operating load impedance 1 Calculate the total paralleled impedance of the 4 Ohm group first by dividing 4 Ohms by 2 4 2 2 Ohms 2 Multiply 2 by 4 for the S4 setting 8 Ohms 3 Calculate the...

Страница 5: ...LLATION COMMON IR BUS SYSTEM Fig 3 illustrates a typical installation using three RAT1 s along with other Xantech products in a 4 room multi room system The principles shown should be used as a guide...

Страница 6: ...outlet on the A V receiver or amplifier system When the switched outlet is ON 12 Volts from the 786 00 passes through one of the 4 bus conductors STATUS line to the LED indicators NOTE A resistor can...

Страница 7: ...Receiver R L MAIN ROOM EQUIPMENT AREA ETC 782 00 Power Supply To 120 V AC unswitched 786 00 STATUS power supply Plug into a SWITCHED AC Outlet on A V Receiver see text A V RECEIVER AMPLIFIER ETC Back...

Страница 8: ...onal 793 00 s These can be easily daisy chained as shown in Fig 5 5 SinceaDedicatedIRBussystemisused eachoftheRAT1 s andMIRV1 s canoperatewiththesame IR Code Group number In this case the Code Group n...

Страница 9: ...2 00 Power Supply To 120 V AC unswitched A V RECEIVER AMPLIFIER ETC Back Panel IR Receiver i e cabinet mounted for IR control in main room 283 00 Emitter 283M Blink IR Place on FRONT Panel IR Sensor C...

Страница 10: ...EA ST G V ST G V FROM AMPLIFIER SPEAKER TERMINALS 786 00 Status Power Supply 782 00 Power Supply To 120 VAC unswitched IR IR Fig 6 Driving Two Speaker Pairs From One RAT1 INSTALLATION cont d 12VDC 12...

Отзывы: