MIRV1

4.

MUTE ON

/

OFF

.   Separate ON / OFF buttons mute and release the signal on the RAT1 without

knowing what the status is.  This is very helpful in a remote room when all adjustments are made “blind”
without any visual aid for status.

NOTE

:  Mute is released (turned off) when a VOLUME or Preset Level  button is pressed, in addition

to MUTE OFF.

5.

Code Group Numbers. 

 If more than one MIRV1, RAT1, or RGC11 is used in a common IR bus

controlled system, or is included with other Xantech products that respond to RC68+  commands,
different code groups can be assigned, by the installer, to avoid mutual interaction.  Refer to the RC68+
instructions for code group setting procedures.

NOTE:  

When shipped from the factory, the MIRV1 & the RAT1 are set to code group number

30.  Be sure to set the RC68+ to the same number!

INSTALLATION

Using One MIRV1 to Control One RAT1

Fig. 3 illustrates such a system. It is configured as
follows:

1. Connections are made as shown.  In this

basic system, the RAT1 volume action is
controlled exclusively by manual rotation of
the MIRV1.  No IR control is used.

NOTE:

  When making the 3-conductor bus

connections, be sure to carefully match up
the terminals according to their markings as
follows: 

 IR IN, GND 

and

 +12V.

2. In this system, the MIRV1 sends out control

codes to the RAT1 (via the 3-conductor bus)
to execute volume adjustments.  As you
rotate the knob, the LED Status Indicator will
blink until the knob and the RAT1 come to
rest at the desired volume setting.

NOTE:

  In this basic application, the STA-

TUS terminal on the MIRV1 is not connected.
The LED Status indicator in the MIRV1 knob,
therefore, will remain OFF except when it
blinks during knob rotation.

3. Since, in this case, a single RAT1 is used with

one MIRV1, each can operate with the same
IR Code Group number as received from the
factory.

4. A 786 Power Supply  is shown powering the system.  If additional MIRV1s, IR Receivers, Keypads,

etc. are used, then the 782-00 Power Supply is recommended.  See the RAT1 installation instructions
for additional power supply recommendations.

5. Since only one pair of speakers and one RAT1 are used, the impedance jumpers on the RAT1 are set

to S1.

Using Two MIRV1's to Control One RAT1

The sytem shown in 

Fig.4

 is similar to 

Fig.3

, except a second MIRV1 contarols the same RAT1 from a

different location in a large room installation.  An additional pair of speakers is used to acoustically cover
the large area.

Fig. 3  

A Basic MIRV1 Remote Room Volume Control System

+12VDC

GROUND

ST
A

TUS

IR IN

SYLMAR,

CA

MIR

V1

MOTORIZED VOLUME

CONTROLLER

S8

S4

S2

S1

L+ L– R– R+

L+ L– R– R+

AMPLIFIER

INPUT

SPEAKER

OUTPUT

STATUS

POWER

IR IN

ST

A

TUS

GND

+12VDC

12VDC

R

L

+

+

MIRV1

Volume

Controller

FROM AMPLIFIER

SPEAKER TERMINALS

786-00

Power Supply

To 120 V AC

(unswitched)

XANTECH

S-62/64/66

Wall Speakers

3-Conductor Bus

REMOTE ROOM

RAT1

REMOTE  AUTO TRANSFORMER

SYLMAR, CA

®