ISM4 INSTALLATION & PROGRAMMING MANUAL
17
Figure 8 ISM4 Expansion Connections
1.
Using a
1-Foot Mono Cable
(Xantech Part No 6017400), connect the
Expansion Jack
on the
Primary ISM4
to the
Source 1 “Sense In”
on the
First Expansion ISM4
.
2.
If using
additional ISM4s
, repeat
Step 1
for each additional ISM4 as shown in
Figure 8
.
3.
Connect the included
Power Supplies
, one to each ISM4.
4.
Connect the
Sensors
and
Emitters
as described the Sections:
Connections/Home Theater System
or
Connections/Multi-Zone System
.
NOTE 1:
The
Source 1 “Sense In”
on the
ISM4 Expansion units
is used for
System Status
as referenced
to the
System Reference Device
. There is no required
IR Emitter
connection to the
Source 1 IR Outs
on
the
ISM4 Expansion units
.
NOTE 2:
If using the Expanded application with a
multi-zone controller
, there would be
no
required
IR
Emitter
connection to the
Primary ISM4 Source 1 “IR Out “
as shown in
Figure 8
.