OMMISSIONING
28
4.5
Connecting the datalogger to the measuring
environment
This section describes how to connect the datalogger to the measuring
environment.
CAUTION
Device damage due to incorrect connection sequence
The incorrect connection sequence can lead to abnormal
behavior or destruction of the datalogger.
According to the numbering of the subsections,
connect the interfaces first and then the power
supply.
Please note the correct connection sequence from
top to bottom within the subsection.
4.5.1
Interfaces
Observe pin assignments
Please note the port pin assignments when connecting
the datalogger with the measuring environment. Wrong
pin assignments lead to measurement errors.
Please note the following sequence:
Connect the data cables of all data buses to be monitored in the
measuring environment.
Connect the data cables to the appropriate datalogger ports.
Wherever possible, tighten the connector screws on the datalogger and
in the measuring environment.
The datalogger is connected to all data buses to be monitored.
Loss of data due to port disconnections
To avoid data loss, never disconnect the datalogger
during the current recording from connected data buses.
Furthermore, make sure that all connectors are firmly
attached and the screws are tightened.
Содержание XORAYA N4000
Страница 1: ...User Manual XORAYA N4000 XORAYA N4000 Version 1 1 6...
Страница 70: ...USER MANUAL XORAYA N4000 XORAYA N4000 XORAYASUITE 70 RS 232...
Страница 185: ......
Страница 186: ......
Страница 187: ......
Страница 188: ......
Страница 189: ......
Страница 190: ......
Страница 191: ......