background image

 

4. Use the menu buttons UP/DOWN?

 to go to menu item 

4. MESSAGE

. Press OK to select this menu item. You can 

also go to this menu item directly by pressing a 4 on the number pad. 
5. Press 1 for 

RECORD

6. The display now shows 

PLEASE WAIT.

 

7.  When  the  display  reads 

SPEAK  NOW

  you  can  record  your  message  (max.  12  seconds).  The  distance  to  the 

microphone should be more or less around 30 cm. 
8. After recording, wait until the 

RECORD/REPLAY

 option comes up again. 

9. Press 2 (REPLAY) to listen to the recorded message. 
10. Press CLEAR to quit the menu. To confirm this choice, press 1 for Yes or 2 for No. If you choose Yes, you 
will quit the menu. If you choose No, you go back to the first menu item.  
 

 
6. Using the Pr Security System 
 
6.1 Setting the alarm 

The system has two different alarm functions: 
 
1) 

ARM AWAY

: Full alarm. All registered Sensors will be activated. 

2) 

ARM  HOME

:  Partial  alarm.  All  Door/Window  sensors  will  be  activated,  but  the  motion  detectors  are  not 

armed. This means you can walk around the house, while the ‘shell’ of is protected. 

a) A 

single

 press arms all Door/Window Sensors 

b)  A 

double

  press  of  ARM  HOME  results  in  every  sensor  to  be  active  in  zones  1-16  but  motion 

detectors are still not active in zones 17-30. All Door/Window Sensors are however active in zones 
17-30. 

 
+Switching on the ARM AWAY function  

 
Via the console 

Press the ARM AWAY button on the console. The system will be activated after a short delay (delay can be set, 
see exit delay 8.1). During the delay you will hear a couple of tones at the same pitch, and the display will read 

EXIT DELAY

 
After  switching  the  system  to 

ARMED AWAY

  mode,  the  entry  delay  will  be  used  for  DS18  Door/Window  Sensors 

(DS18 switch set to MAX) when you enter the house. This means you have enough time to switch off the system 
via the console without triggering the alarm. The delay times can be changed, see 8.1. 
Also Motion Sensors registered to zone 15 and/or 16 will have an entrance delay according the time set. This 
gives the opportunity to have entrances secured via Motion Sensors.  

 

Besides the Security function, the 

ARM AWAY

 button on the console reflects Temperature Setback options, to 

be used for energy saving: 
Press the 

ARM AWAY

 button on the console. The system will be activated after a short delay: 

-A 

single 

press: Thermostat remains setting of respective TS10. Display will show 

COMFORT. 

-Press 

twice

; thermostat level will be set to Economy Level. Display will show 

ECONOMY.

 

-

Third

 press: thermostat level will be set to Frost Level. Display will show 

FROST

The  first  press  of  ARM  AWAY  will  leave  the  thermostat  working  exactly  as  it  would  do  if  the  system  was  not 
armed i.e. it will follow the set-point on the thermostat(s) unless there is a timer event set which could change it.  

 

Via the Key Chain Remote Control KR18 

Press the ARM button. The alarm is switched on instantly. 

 

Via the Comfort Remote Control SH600 

Set the slide switch to SEC. Press the ARM AWAY button. The alarm is switched on instantly. 

 
+Switching on the ARM HOME function 

 
Via the console 

Press the ARM HOME button on the console. The alarm is switched on instantly. 

-A 

single

 press arms all Door/Window Sensors. Display will read 

ARM HOME 1

-A 

double

 press of ARM HOME actives all Sensors in zones 1-16. Display will read 

ARM HOME 2

 

Via the Key Chain Remote Control KR18 

You cannot switch on the ARM HOME function with this remote control. 

Via the Comfort Remote Control SH600 

Set the slide switch to SEC. Press the ARM HOME button. The alarm is switched on instantly. 

Содержание PROTECTOR+

Страница 1: ...USERS MANUAL PROTECTOR SYSTEM AND BASE CONSOLE INSTRUCTIONS ...

Страница 2: ...t 4 2 Motion Detector MS18 4 2 1 Mounting the Motion Detector MS18 4 2 2 Using the Motion Detector 4 2 3 Registering a Motion Detector with the Console 4 3 Additional Wireless Sensors optional 4 3 1 Registering an additional Wireless Detector 4 4 Thermostat TS10 optional 4 4 1 Registering a Thermostat with the Console 4 4 2 Using the Thermostats 5 Setting up the Security Base Console SC28 5 1 Sett...

Страница 3: ... be used inside and only in dry spaces Do not expose the components to rain or humidity Do not use the product close to a bath swimming pool etc Only connect the adapter to the mains after checking whether the mains voltage is the same as the values on the rating labels Never connect an adapter or power cord when it is damaged In that case contact your supplier Avoid strong mechanical tear and wea...

Страница 4: ...r wired sensors zone 31 32 Selectable ALWAYS sensors for emergency purposes 2 Arm Home Modes by pressing ARM HOME once or twice ARM HOME once only D W sensors will be armed Second key press arms also Motion Sensors in zones 1 16 Definable entrance delay on Motion Sensors registered to zones 15 and or 16 Can register a mix of up to 16 wireless remote controls KR18 KR28 SH600 and or emergency sensor...

Страница 5: ... not installed 5 Tamper contact 6 AC power supply adapter connections 7 ARM HOME button Alarm function for when you are at home All Door Window Sensors are activated but the Motion Detectors remain unarmed 8 Built in Speaker 9 ARM AWAY button Full alarm All sensors are activated 10 Built in Microphone 11 Wired inputs 12 Telephone connection 13 Emergency battery compartment RECHARGEABLE BATTERIES O...

Страница 6: ...needs to be programmed in with the telephone numbers to be able to dial out see 5 2 2 1 2 Connecting the AC adapter Connect the AC adapter to the corresponding connection 6 Plug the flying lead of the adapter into a 230V 50Hz wall socket You can fixate the wire by looping it behind the hooks on the back of the console When connecting the adapter and opening the top compartment of your console you ...

Страница 7: ...hoose any of the other available languages as follows To access the menu press the menu UP or menu DOWN button The display now shows ENTER PIN Enter the 4 digit PIN code factory setting 0000 See 8 3 for changing the PIN code The display is cleared and shows a for each number entered When the PIN code has been entered correctly the first menu item will show up on the display Use the menu buttons UP...

Страница 8: ...OICE MAIL 11 2 SENSOR MODE Use sensors as emergency sensor See 9 5 SENSOR 27 32 NO ON OFF Used for setting zones 27 to 32 to send Home Automation ON or OFF commands on House Code 1 and Unit Code 7 12 in respond alarm trigger from respective zones 27 32 e g zone 27 is related to UC 7 29 to 9 etc COMFORT To set COMFORT ECONOMY and FROST level temperatures LANGUAGE ENGLISH FRANÇAIS DEUTSCH NEDERLANDS...

Страница 9: ...an be registered with your console When pressing the ARM button the LED should flash quickly a few times When the LED lights up and stays lit you need to re initialize the KR18 3 1 2 Registering the Key Chain Remote Control with the Console 1 To access the menu press either the menu UP or DOWN button The display now shows ENTER PIN 2 Enter your 4 digit PIN code factory setting 0000 See 8 3 for cha...

Страница 10: ...e plastic cover of the text window you can note which Home Automation Modules can be controlled with each key 7 House Code Switch Used for setting the X10 system Address 3 2 1 Using the Comfort Remote Control IMPORTANT When inserting the batteries the switch should not be in setting 2 1 Install batteries Open the battery compartment on the back of the remote control and place the battery 4x AAA pr...

Страница 11: ...me of your door or window Do not close the casing yet 2 Mount the magnet on the moving part of your door of window Make sure that the arrows on the transmitter part see the arrow and the magnet are facing each other when the door or window is closed Keep the distance between the transmitter part and the magnet when door or window is closed as small as possible max 5 mm Door Window Sensors may be h...

Страница 12: ...ll read ZONE 1 SET A memory space for a sensor is called a zone If you have more than 1 sensor installed it will show e g ZONE 2 SET ZONE 3 SET ZONE 30 SET You can choose in which zone you want to install the sensor If you want to install the sensor in zone 3 press 3 on the number pad before executing step 5 It s advisable to write down which zone contains which sensor There s space reserved at th...

Страница 13: ... any movement during registration Test mode Testing the location of your motion detector 1 Set the switch 5 to 1 2 Press the TEST button 6 until the indicator 1 flashes twice 3 Wait 20 30 seconds 4 Walk in front of the sensor The indicator 1 lets you know when a movement has been detected This allows you to check whether the sensor has been mounted on the right place 5 Press the TEST button again ...

Страница 14: ...ectors based on remote panic function or up to 30 sensors in case of wireless alarm sensor function 6 Repeat step 5 for every additional sensor you wish to register 7 Press CLEAR to go back to the first menu item Press CLEAR again to quit the menu If required you can remove Additional Wireless Sensors from the memory This method is described in 8 2 All information on mounting the respective detect...

Страница 15: ...d shows a for each number entered 3 When the PIN code has been entered correctly the word INSTALL will displayed 4 Use the menu buttons UP DOWN to go to menu item 3 PHONE NUMS Press OK to select this menu item You can also go to this menu item directly by pressing a 3 on the number pad 5 Use the menu buttons UP DOWN to go to the memory space where you want to enter a telephone number PHONE 1 PHONE...

Страница 16: ...8 Door Window Sensors DS18 switch set to MAX when you enter the house This means you have enough time to switch off the system via the console without triggering the alarm The delay times can be changed see 8 1 Also Motion Sensors registered to zone 15 and or 16 will have an entrance delay according the time set This gives the opportunity to have entrances secured via Motion Sensors Besides the Se...

Страница 17: ...witch off the system by entering your PIN code on the number pad of the console After entering your PIN code the display will read DISARMED 6 5 Error messages The numbers 1 32 in the display refer to up to 32 zones read sensors These represent up to 30 Door Window Sensors and or Motion Detectors you install plus the 2 hard wired zones The numbers show open zones problem zones and bypassed zones by...

Страница 18: ...usehold equipment or TL PL lights into the module Use an AM12 Appliance Switch Module or a LM15 Lamp Module for these types of loads 7 4 Alarm functions of the Lamp Dimmer Modules When Arming the system via the console the lamps on A1 and A2 will be switched on during the Exit Delay As soon as the system is activated the lamp will be switched off When Arming the system via remote control the lamps...

Страница 19: ...play will read 1 HOME CNTRL and 2 HEAT COOL select respective timer to set either option 1 for control of lights and appliances or option 2 for timed temperature setbacks Use the menu buttons UP DOWN to check timers you previously set The top menu item is always called NEW TIMER unless all 14 timer points have been set 7 The display will read CHOOSE DAYS Use the number keys to enter the DAYS where...

Страница 20: ... 8 on the number pad 5 Select ENTRY DELAY EXIT DELAY ANSWER DELAY or DIAL DELAY and press OK 6 Enter the time required 1 99 seconds Press OK Press CLEAR to delete the values entered 7 Press CLEAR again to quit the menu The entry delay only works for the DS18 Door Window Sensors if set to MAX as well as Motion Sensors registered to zone 15 and or 16 MS18 motion detectors registered to other zones w...

Страница 21: ...you go back to the first menu item 9 2 Activating the chime 9 2 1 Built in Chime The console can when in DISARMED mode sound a chime ding dong when a door armed with a Door Window Sensor is opened This ensures that you will always hear if someone is entering your house or small children open a door This function is activated in the factory settings 1 To access the menu press the menu UP or menu DO...

Страница 22: ...now reads SET ALWAYS SENSORS You can see on your display top and bottom which zones and sensors have been registered 7 If you want to turn zone 31 into an emergency sensor enter 31 on the number pad and press OK Zone number 31 will start flashing 8 If you also want to turn zone 5 into an emergency sensor enter 5 on the number pad and press OK Zone number 5 will start flashing 9 If you want to turn...

Страница 23: ...iren SH10 to address B5 HC 1 UC 5 ATTENTION When using a security system the extra sirens will always work in case of an alarm even when the system is set to silent alarm The Siren SH10 is meant for indoor use and can be plugged into any wall socket 230V 50Hz If Chime is enabled opening a D W sensor gives a pleasant 6 tone message It also gives tones for Exit Delay when Arming one single tone once...

Страница 24: ...u press the menu UP or menu DOWN button The display now shows ENTER PIN 2 Enter your 4 digit PIN code factory setting 0000 See 8 3 for changing the PIN code The display is cleared and shows a for each number entered 3 When the PIN code has been entered correctly the word INSTALL will show up on the display 4 Use the menu buttons UP DOWN to go to menu item 7 OPTIONS Press OK to select this menu ite...

Страница 25: ...ress set all thermostat levels to Frost level as set to the console 11 Telephone functions 11 1 Calling the security system The SC28 alarm system is equipped with a call in function This means that you can dial in to the console remotely via any telephone or mobile phone You can also control your lights devices and temperature setbacks via your phone The system has a built in speech chip that guid...

Страница 26: ...Frost Setting Note The thermostat settings 88 or 88 will only work if the console is Armed Away Otherwise you will get an Error message As soon as you override temperature settings by telephone the only choices are the set point on the thermostat economy or frost The comfort setting of the individual thermostats which is set in the options can only be used by use of a timer event Using the telepho...

Страница 27: ...lace the batteries within 30 seconds If the console does not respond to your remote control after replacing the batteries press the PANIC button on your remote control You now need to reregister the remote control using the procedure described in 3 1 2 Door Window Sensor DS18 2x AAA batteries and Motion Detector MS18 2x AA batteries The console checks the battery status of the DS18 sensor If the b...

Страница 28: ...vating the zone What to do if you hear a repetitive one tone signal when activating the alarm This is normal When activating the alarm there is an exit delay of one minute to leave your house You can alter this delay see 8 1 After one minute the tone will stop and the system will be switched on What if you cannot switch the light on or off using the Lights ON or Lights OFF button on the remote con...

Отзывы: