- 11 -
Cleaning the Filter Tube
1. Turn off the power to the unit and
allow the desoldering gun to
cool prior to removing the filter
.
a. Press grip assembly release button (see diagram below)
b. Grip assembly will slide back (see diagram below)
c. Remove the filter chamber (see diagram below
a.
c.
b.
2. Flex the spring filter to break up its contents and dispose of the
waste.
CAUTION: The filter chamber may be very hot. Use caution to
avoid accidental burn.
Front
Chamber
Seal
Spring
Filter
Filter
Chamber
Fiber
Filter
Filter assembly components need replacing when any of the following
occur:
• The front seal should be replaced when becomes stiff or cracked
• The fiber filter should be replaced if there is too much flux or
solder build up on the filter surface
• The spring filter should be replaced if it becomes more than two-
thirds of the way blocked and are unable to clean it