- 9 -
HOT AIR GUN IN HANDS-FREE TELESCOPIC ASSEMBLY
NOTE: The hot air gun should
NEVER
be in the vertical position when
the unit is initially turned on. It can be used vertically with the
appropriate air flow and then should be returned to the side holder
for cool down.
Hot Air Gun in Hands-Free
Telescopic Assembly
1. Attach the cord to the side of the machine using the attached clip.
2. With the nozzle pointing down, insert the hot air gun into the hot air
gun holder.
3. Adjust the bottom silver screws first to center the hot air gun nozzle
in the center of the holder.
4. Adjust the black thumb screws to snuggly hold the plastic just
above the metal area of the hot air gun to center and secure it in
the assembly
• When using the hot air gun in the vertical holder, the air flow must
be turned up to at least 4 or higher the
ENTIRE TIME
the hot air
gun is in this position. If the air flow is not sufficient the unit will
be damaged and the life of the heating element will be greatly
reduced.
CAUTION! IF THIS IS NOT FOLLOWED
the hot air gun will
overheat and may cause the polymer on the front of the hot air gun
to melt and get red hot from the intense heat.
• After using the hot air gun, place it back into the side holder, and
allow the unit to initiate the cool down cycle until the display reads
“---”. Then power can be turned off.
• Always shield the surrounding components while using the hot air
gun. Failure to do so could cause other components to become
unsoldered and blow off of the board.