- 5 -
INITIAL SET-UP
1. Place the hot air gun in the vertical position in the upright tower
holder.
Ensure the hot air gun is fully seated so the edge is
resting against the base of the holder.
See photo below.
Hot Air Gun Correctly
Seated in Upright
Tower Holder
2. Plug the 3-Prong AC cord into a 110/120V grounded outlet to
prevent electric shock or injury.
3. Turn ON the power switch located on the lower left front of the unit.
4. The left side of the display will indicate °F or °C in red, showing
the unit of measurement for the temperature. All three of the LED
displays will show “---”, indicating that the unit is in Standby Mode.
5.
Push the Hot Air Temperature Adjustment Buttons (▲ or ▼ ) on
the left side of the unit to set the hot air gun temperature. The
temperature range is 212°F ~ 932°F / 100°C ~ 500°C.
6.
Push the Air Flow Adjustment Buttons (▲ or ▼ ) on the right side
of the unit to set the hot air gun temperature. The air flow range is
1-120.
CAUTION
When using a temperature higher than 300°C/572°F the air flow
should be set at 45 or higher. This will prevent damage to the hot
air gun and increase the life of the heating element.
7. When the hot air gun is removed from the holder it will start
blowing air and ramp up to the programmed temperature and air
flow quickly.