background image

4. Status LED and wiring description 

 

Device status LED:

 

 

GSM LED - Red 

Status 

Description 

Off 

Phone module switched off or in “sleep mode” 

Blinking 

600 ms On / 600 ms Off 

SIM card not inserted, Pin code enable (to be 
removed) or GSM network authentication in 
progress 

Blinking

 

100 ms On / 3 sec Off 

GSM network successfully authenticated 

Blinking

 

2 x 100 ms On / 2,5 sec Off

 

GPRS Server successfully connected

 

 

GPS LED (Dual-mode GPS/GLONASS receiver) - Green 

Status 

Description 

Off 

GPS/GLONASS receiver switched off or in “sleep 
mode” 

Blinking 

1 sec On / 1 sec Off

 

Invalid GPS/GLONASS fix 

On 

GPS/GLONASS position successfully acquired, 
valid fix 

 
 

Attention please:

 Before power up the device 

it’s necessary to insert the SIM card into the 
card reader which is placed on the bottom side 
of the device (please remove the black panel in 
order to accede the reader). 

 

Attention please: 

By using a cell phone, please 

disable the SIM card Pin code before inserting it 
into the device. 
 
 
 
 
 
 
 
 
 
 

5. Quick start 

 

1- After inserting the SIM card, please turn ON the device by connecting Red  

1-

 wire (Positive) and Black wire (Negative) to main power supply. Please  

1-

 connect also White wire (Input 1) to ACC signal (+15) in order to maintain  

1-

 the device On during the testing procedure. When the device is successfully  

1-

 connected to power supply then both 

red 

and 

green LED

 start blinking. 

 
2- Please wait for few seconds till the phone module successfully authenticate  

1-

 to the GSM network. When the connection is established then 

red LED

  

1-

 starts blinking (2 x 100 ms On / 2,5 sec Off). 

 
3- In order to get the first valid fix, it’s necessary to place the device in an  

1-

 appropriate place (open sky) avoiding any metal surface obstructing it.  

1-

 When GPS/GLONASS is fixed then 

green LED

 lights steady (On). 

 
4- By sending an SMS message to the unit it’s possible to pair your mobile  

1-

 phone number (up to 2 numbers) and to assign an ID name to the device  

1-

 (max 12 characters). The SMS string you need to send is:  

1-

 

#CFG*

Cell.1

*

Cell.2

*

Name

1-

 Example of string you need to send for enabling one SMS phone number  

1-

 only and for assigning an ID name: 

1-

 

#CFG*

+391234567890

**

X360

#

 

 
5- When the device is turned ON and GSM module is ON (red LED is blinking)  

1-

 it’s possible to query the position from your mobile phone by sending 

XPOS

  

1-

 SMS string. Through SMS channel it’s also possible to control a pre-defined  

1-

 output from remote. To enable the predefined output please send 

XON

  

1-

 command string by SMS; to disable it please send 

XOFF

 command string. 

1-

 By sending 

XCALL

 SMS, it’s possible to receive to your mobile phone a 

1-

 “Silent listening” call from the device (optional external microphone must be 

1-

 connected to the unit), and also a “2 Ways” call by sending 

XCALL2

 SMS  

1-

 string (both optional external microphone and speaker must be connected  

1-

 to the unit). 

1-

 Moreover, it’s possible to manage “Auto-Target” function from 3 predefined  

1-

 sizes of radius: Small, Medium e Large. Based on which radius you want to  

1-

 enable, the command strings to send by SMS are: 

XGEOSON

 (Small radius 

1-

 Target enabled), 

XGEOMON

 (Medium radius Target enabled) and  

1-

 

XGEOLON

 (Large radius Target enabled); to disable them please send:  

1-

 

XGEOSOFF

 (Small radius Target disabled), 

XGEOMOFF

 (Medium radius  

1-

 Target disabled) and 

XGEOLOFF

 (Large radius Target disabled). 

1-

 Only pre-defined numbers from Control Base Center or by CFG SMS self- 

1-

 setting procedure (please refer to point N.4) are able to manage these  

1-

 functions. 

 

Attention please:

 for a better management and functionality the device must 

be pre-configured and fully tested from the reference Control Base Center. 

 

Содержание X-360

Страница 1: ...o change without notice Responsible for placing on the EU market D Lgs 269 2001 Art 13 Com 4 X TraX S r l Via Per Lecco 24 26 23848 Oggiono LC ITALY _______________________________________________________________ Manuale di Installazione X 360 10 2019_rev 02_EN Installation Manual X TraX Group X 360 Vehicle tracker ...

Страница 2: ...king and monitoring purpose It s suitable for different applications such as vehicle security monitoring asset fleet management The unit is equipped with built in 2 4GHz RF receiver for managing dedicated smart accessories and with RS 232 Serial port up to 3 ports available which allows to interface external accessories for different utilities and services such as I O expansion box Moreover the un...

Страница 3: ...PRS OFF G Sensor ON 18mA DC 12V GSM GPRS and GPS GLONASS Status LED Gemalto dual band GSM GPRS module Communication channels SMS and GPRS TCP UDP GSM and GPRS channels simultaneously Hands free and Voice wiretapping optional Unit programming by Serial USB SMS or GPRS SIM card PIN code protection 5 VIP SMS numbers Sophisticated power saving mode setting Mileage Counter by GPS GLONASS Service functi...

Страница 4: ...ting it 1 When GPS GLONASS is fixed then green LED lights steady On 4 By sending an SMS message to the unit it s possible to pair your mobile 1 phone number up to 2 numbers and to assign an ID name to the device 1 max 12 characters The SMS string you need to send is 1 CFG Cell 1 Cell 2 Name 1 Example of string you need to send for enabling one SMS phone number 1 only and for assigning an ID name 1...

Страница 5: ... Counters and up to 4 digital Outputs all Negatives IG Function Connecting Red Black wires from AVL unit to Positive Negative signals of vehicle main battery it s possible to detect Engine On Engine Off status without connecting Input 1 to Ignition Key signal Enabling this function the Input 1 wire becomes available for other use In order to let this function enable please take contact with the C ...

Страница 6: ...atus without connecting Input 1 to Ignition Key signal Enabling this function the Input 1 wire becomes available for other use In order to let this function enable please take contact with the C B S providing them the exactly voltage levels measured on the main battery circuit on both Engine On Engine Off conditions Power supply Red Positive DC 8 30V Power supply Black Negative GND IG Function Out...

Отзывы: