3.
A maximum of 24 wireless alarms can be interconnected on the same network.
4.
The model can only be interconnected with other X-Sense Link
+
wireless interlinked alarms.
How to Disconnect
Quickly press the test/silence button 4 times; the smoke alarm will beep once. Then, hold down the
button until it beeps once more to disconnect. After disconnecting, it can be reconnected to the same
network, or added to a new network.
NOTE: The X-Sense Link
+
wirelessinterlinked alarms in one multi-pack have already been
interconnected. To create a new network, you will first need to disconnect each alarm
individually in this multi-pack to avoid having them all join the same network.
Alarm Test
The smoke alarm must be properly attached to the mounting bracket before it can be tested; otherwise,
it will not turn on. Be sure to test your smoke alarms when you turn them on for the first time, or when
the group configuration has changed. In addition to the weekly tests you should perform, it is
recommended to test the alarm after returning from a long trip or vacation.
If your X-Sense Link
+
SD19-W/SD20-W is interconnected to other wireless smoke alarms, we
recommend that every individual smoke alarm is tested during the weekly test.
Test a single alarm
Test all interconnected smoke alarms
Action
Press the test/silence button.
Hold down the test/silence button
Indication
The alarm will beep 3 times every
4 seconds.
The LED will flash red during the
test and give an audible signal.
After testing, the alarm will
automatically enter standby mode.
The initiating smoke alarm will beep
continuously with the red LED flashing.
Other interconnected smoke alarms in
the network will receive the signal after
5
seconds,
and
they
will
beep
continuously with the red LED flashing.
Release the test/silence button and all the
smoke alarms will stop testing.
The testing of the units should be
completed within 3 minutes.
After
testing,
the
alarm
will